Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
The marsh cone as a viscometer: Theoretical analysis and practical limits
Abstract In this study, we have investigated the possibility of using the Marsh cone as a viscometer. Rheological measurements along with digital image recording of Marsh cone flow on glycerol-water mixes were carried out. The equations needed to solve the flow problem are written in the case of a purely Newtonian viscous fluid. We show that flow time can be directly linked to the Newtonian viscosity. Flow time is proportional to viscosity. The Marsh cone is then used to test several cement pastes and measured flow time is compared to predicted flow time. The correlation between flow time and cement pastes apparent viscosity stays valid only for no yield stress cement pastes and for flow time higher than about 15 s.
Résumé Dans cette étude, on a évalué la possibilité d'utiliser le cône de Marsh en tant que viscosimètre. Des mesures rhéologiques, couplées avec des enregistrements d'images numériques d'écoulements au cône de Marsh, de mélanges de glycérol et d'eau ont été effectués. Les équations nécessaires pour résoudre le problème ont été écrites dans le cas d'un fluide purement visqueux. On montre alors que le temps d'écoulement est proportionnel à la viscosité. Le cône de Marsh est ensuite essayé sur des p⋲tes de ciment pour lesquelles le temps d'écoulement mesuré est comparé à celui calculé. La corrélation entre le temps d'écoulement et la viscosité apparente reste valide uniquement pour les pâtes de ciment n'ayant pas de seuil d'écoulement et pour des temps d'écoulement supérieurs à environ 15 s.
The marsh cone as a viscometer: Theoretical analysis and practical limits
Abstract In this study, we have investigated the possibility of using the Marsh cone as a viscometer. Rheological measurements along with digital image recording of Marsh cone flow on glycerol-water mixes were carried out. The equations needed to solve the flow problem are written in the case of a purely Newtonian viscous fluid. We show that flow time can be directly linked to the Newtonian viscosity. Flow time is proportional to viscosity. The Marsh cone is then used to test several cement pastes and measured flow time is compared to predicted flow time. The correlation between flow time and cement pastes apparent viscosity stays valid only for no yield stress cement pastes and for flow time higher than about 15 s.
Résumé Dans cette étude, on a évalué la possibilité d'utiliser le cône de Marsh en tant que viscosimètre. Des mesures rhéologiques, couplées avec des enregistrements d'images numériques d'écoulements au cône de Marsh, de mélanges de glycérol et d'eau ont été effectués. Les équations nécessaires pour résoudre le problème ont été écrites dans le cas d'un fluide purement visqueux. On montre alors que le temps d'écoulement est proportionnel à la viscosité. Le cône de Marsh est ensuite essayé sur des p⋲tes de ciment pour lesquelles le temps d'écoulement mesuré est comparé à celui calculé. La corrélation entre le temps d'écoulement et la viscosité apparente reste valide uniquement pour les pâtes de ciment n'ayant pas de seuil d'écoulement et pour des temps d'écoulement supérieurs à environ 15 s.
The marsh cone as a viscometer: Theoretical analysis and practical limits
Roy, R. (Autor:in) / Roussel, N. (Autor:in)
Materials and Structures ; 38 ; 25-30
01.01.2005
6 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
The Marsh Cone as a viscometer: Theoretical analysis and practical limits
Online Contents | 2005
|The marsh cone as a viscometer: Theoretical analysis and practical limits
Online Contents | 2005
|The Marsh Cone as a viscometer: theoretical analysis and practical limits
British Library Online Contents | 2005
|Viscometer for particle sizing
British Library Online Contents | 2005
British Library Online Contents | 2007