Design of Anchorages in Connections Using Post-installed Reinforcing Bars
The use of post-installed reinforcing bars to connect existing concrete elements to newly cast concrete has increased significantly in the last decade. Very common applications are connections between reinforced concrete beams/slabs and columns/walls or reinforced concrete columns/walls and foundations. The design of such connections is clearly limited by the need to use straight reinforcing bars. Consequently, a clear understanding of the unique load-displacement properties of the post-installed reinforcing bars, the necessary loading and installation conditions, and the stresses introduced in the concrete members is required. In this paper design methods based on Eurocode 2 and a new approach considering the actual bond-splitting performance of the adhesive are compared and applied to some case studies where post-installed reinforcing bar systems are used for moment resisting connections. Through the design of typical connections, the challenges and the opportunities associated with the use of post-installed reinforcing bars and their proper design are explored.
Design of Anchorages in Connections Using Post-installed Reinforcing Bars
The use of post-installed reinforcing bars to connect existing concrete elements to newly cast concrete has increased significantly in the last decade. Very common applications are connections between reinforced concrete beams/slabs and columns/walls or reinforced concrete columns/walls and foundations. The design of such connections is clearly limited by the need to use straight reinforcing bars. Consequently, a clear understanding of the unique load-displacement properties of the post-installed reinforcing bars, the necessary loading and installation conditions, and the stresses introduced in the concrete members is required. In this paper design methods based on Eurocode 2 and a new approach considering the actual bond-splitting performance of the adhesive are compared and applied to some case studies where post-installed reinforcing bar systems are used for moment resisting connections. Through the design of typical connections, the challenges and the opportunities associated with the use of post-installed reinforcing bars and their proper design are explored.
Design of Anchorages in Connections Using Post-installed Reinforcing Bars
Lecture Notes in Civil Engineering
di Prisco, Marco (Herausgeber:in) / Menegotto, Marco (Herausgeber:in) / Cattaneo, Sara (Autor:in) / Genesio, Giovacchino (Autor:in) / Piccinin, Roberto (Autor:in)
Italian Concrete Conference ; 2021 ; Naples, Italy
10.09.2023
12 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Seismic Design of Anchorages Using Post-installed Reinforcing Bars
Springer Verlag | 2023
|Tests of anchorages for reinforcing bars
Engineering Index Backfile | 1933
|Post installed rebar end anchorages in reinforced concrete structural connections
TIBKAT | 2022
|Post installed rebar end anchorages in reinforced concrete structural connections
UB Braunschweig | 2022
|