Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental Investigations of Full-Scale Cross-Laminated Timber Concrete Composite Floors
Experimental investigations on full-scale Timber Concrete Composite (TCC) floor systems with various composite connectors are presented in this paper. The stiffness, strength, and failure modes of were evaluated. The 9.2 m long and 2.4 m wide TCC floor segments were comprised of 245 mm thick, 7-ply Cross-laminated Timber (CLT) panels with 150 mm concrete topping connected with three types of shear connectors: (i) self-tapping screws, (ii) steel kerf plates, and (iii) glued-in Holz-Beton-Verbund (HBV) plates. Six TCC floor segments were tested to failure under symmetric four-point bending and three TCC floor segments were tested under torsional bending by applying eccentric loading near the edge. The floor deformations at nine locations and connector slips at CLT-concrete interfaces at eight locations along the length of the floor were measured. The full-scale tests showed that the steel kerf plates—for the selected connector configurations- exhibited the highest capacity and stiffness.
Experimental Investigations of Full-Scale Cross-Laminated Timber Concrete Composite Floors
Experimental investigations on full-scale Timber Concrete Composite (TCC) floor systems with various composite connectors are presented in this paper. The stiffness, strength, and failure modes of were evaluated. The 9.2 m long and 2.4 m wide TCC floor segments were comprised of 245 mm thick, 7-ply Cross-laminated Timber (CLT) panels with 150 mm concrete topping connected with three types of shear connectors: (i) self-tapping screws, (ii) steel kerf plates, and (iii) glued-in Holz-Beton-Verbund (HBV) plates. Six TCC floor segments were tested to failure under symmetric four-point bending and three TCC floor segments were tested under torsional bending by applying eccentric loading near the edge. The floor deformations at nine locations and connector slips at CLT-concrete interfaces at eight locations along the length of the floor were measured. The full-scale tests showed that the steel kerf plates—for the selected connector configurations- exhibited the highest capacity and stiffness.
Experimental Investigations of Full-Scale Cross-Laminated Timber Concrete Composite Floors
Lecture Notes in Civil Engineering
Walbridge, Scott (Herausgeber:in) / Nik-Bakht, Mazdak (Herausgeber:in) / Ng, Kelvin Tsun Wai (Herausgeber:in) / Shome, Manas (Herausgeber:in) / Alam, M. Shahria (Herausgeber:in) / El Damatty, Ashraf (Herausgeber:in) / Lovegrove, Gordon (Herausgeber:in) / Shahnewaz, Md (Autor:in) / Jackson, Robert (Autor:in) / Tannert, Thomas (Autor:in)
Canadian Society of Civil Engineering Annual Conference ; 2021
Proceedings of the Canadian Society of Civil Engineering Annual Conference 2021 ; Kapitel: 34 ; 401-409
17.06.2022
9 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Cross-Laminated Timber Concrete Composite Systems for Long-Span Floors
British Library Conference Proceedings | 2022
|Structural performance of nail-laminated timber-concrete composite floors
BASE | 2017
|Cross laminated timber panels to strengthen wood floors
British Library Conference Proceedings | 2008
|