Seismic Assessment and Strengthening of an Existing Industrial Building
Nowadays, the development of rapid and low-impact structural rehabilitation strategies and techniques is very topical. These prerogatives are essential for the seismic retrofit of industrial buildings, for which the seismic retrofit solution should be selected also accounting for the impact of the interventions on the productive activities. Therefore, a retrofit solution that allows to increase the structural capacity without interfering with the industries production could be preferred with respect to canonical retrofit solutions. In this framework, the aim of the present work is to investigate the efficiency of orthogonal steel exoskeletons for the retrofitting of a steel single-storey industrial building. The investigated case study has poor lateral stiffness and strength. Following a specific design methodology, the various elements of the system were designed, and their efficiency was assessed by means of a non-linear static procedure. Moreover, a local retrofit of the truss to column connections of the MFRs was performed and investigated by means of FEM analysis.
Seismic Assessment and Strengthening of an Existing Industrial Building
Nowadays, the development of rapid and low-impact structural rehabilitation strategies and techniques is very topical. These prerogatives are essential for the seismic retrofit of industrial buildings, for which the seismic retrofit solution should be selected also accounting for the impact of the interventions on the productive activities. Therefore, a retrofit solution that allows to increase the structural capacity without interfering with the industries production could be preferred with respect to canonical retrofit solutions. In this framework, the aim of the present work is to investigate the efficiency of orthogonal steel exoskeletons for the retrofitting of a steel single-storey industrial building. The investigated case study has poor lateral stiffness and strength. Following a specific design methodology, the various elements of the system were designed, and their efficiency was assessed by means of a non-linear static procedure. Moreover, a local retrofit of the truss to column connections of the MFRs was performed and investigated by means of FEM analysis.
Seismic Assessment and Strengthening of an Existing Industrial Building
Lecture Notes in Civil Engineering
Mazzolani, Federico M. (Herausgeber:in) / Dubina, Dan (Herausgeber:in) / Stratan, Aurel (Herausgeber:in) / Tartaglia, Roberto (Autor:in) / Prota, Alessandro (Autor:in) / Milone, Aldo (Autor:in) / Di Lorenzo, Gianmaria (Autor:in) / Landolfo, Raffaele (Autor:in)
International Conference on the Behaviour of Steel Structures in Seismic Areas ; 2022 ; Timisoara, Romania
Proceedings of the 10th International Conference on Behaviour of Steel Structures in Seismic Areas ; Kapitel: 107 ; 966-974
08.05.2022
9 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
SEISMIC STRENGTHENING STRUCTURE AND METHOD FOR EXISTING BUILDING
Europäisches Patentamt | 2016
SEISMIC STRENGTHENING STRUCTURE AND METHOD FOR EXISTING BUILDING
Europäisches Patentamt | 2016
|