Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Structural Health Monitoring of Reinforced Concrete Beam-Column Joints Using Piezoelectric Transducers
Traditional methods for estimating structural deterioration are generally costly and inefficient, especially for non-accessible structural members. However, recent research has demonstrated that electro-mechanical impedance (EMI) or its inverse electro-mechanical admittance (EMA) measurements can be used to continuously monitor the structural integrity of reinforced concrete (RC) civil infrastructures in real-time. In this work, three lead piezoelectric zirconate titanate (PZT) transducers were epoxy-bonded on the external surface of a real-scale RC beam-column joint (BCJ) specimen. An integrated wireless impedance/admittance monitoring system (WiAMS) excites and simultaneously measures the voltage signal response of the PZT transducers in various imminent damage states. Furthermore, a scalar statistical index is employed to quantify the structural damage based on the variation of the PZT output voltage signals between their response at different damage levels and a pristine, undamaged state (initial healthy). The results of this study indicate that through the EMI technique, external epoxy-bonded PZT transducers can reliably evaluate the structural integrity of BCJs.
Structural Health Monitoring of Reinforced Concrete Beam-Column Joints Using Piezoelectric Transducers
Traditional methods for estimating structural deterioration are generally costly and inefficient, especially for non-accessible structural members. However, recent research has demonstrated that electro-mechanical impedance (EMI) or its inverse electro-mechanical admittance (EMA) measurements can be used to continuously monitor the structural integrity of reinforced concrete (RC) civil infrastructures in real-time. In this work, three lead piezoelectric zirconate titanate (PZT) transducers were epoxy-bonded on the external surface of a real-scale RC beam-column joint (BCJ) specimen. An integrated wireless impedance/admittance monitoring system (WiAMS) excites and simultaneously measures the voltage signal response of the PZT transducers in various imminent damage states. Furthermore, a scalar statistical index is employed to quantify the structural damage based on the variation of the PZT output voltage signals between their response at different damage levels and a pristine, undamaged state (initial healthy). The results of this study indicate that through the EMI technique, external epoxy-bonded PZT transducers can reliably evaluate the structural integrity of BCJs.
Structural Health Monitoring of Reinforced Concrete Beam-Column Joints Using Piezoelectric Transducers
RILEM Bookseries
Jędrzejewska, Agnieszka (Herausgeber:in) / Kanavaris, Fragkoulis (Herausgeber:in) / Azenha, Miguel (Herausgeber:in) / Benboudjema, Farid (Herausgeber:in) / Schlicke, Dirk (Herausgeber:in) / Naoum, Maria (Autor:in) / Sapidis, George (Autor:in) / Papadopoulos, Nikos (Autor:in) / Golias, Emmanouil (Autor:in) / Chalioris, Constantin (Autor:in)
International RILEM Conference on Synergising expertise towards sustainability and robustness of CBMs and concrete structures ; 2023 ; Milos Island, Greece
11.06.2023
12 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
British Library Conference Proceedings | 2014
|Rehabilitation of reinforced concrete beam-column joints
British Library Conference Proceedings | 1996
|Reinforced concrete beam-column joints under cyclic loading
British Library Conference Proceedings | 2000
|Seismic resistance of reinforced concrete beam-column joints
Engineering Index Backfile | 1967
|Behaviour of steel reinforced concrete beam-column joints
British Library Conference Proceedings | 2011
|