Microcystin-LR detection based on indirect competitive enzyme-linked immunosorbent assay
Abstract Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria, which cause lots of accidents and threatens human health. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was established and used to detect microcystin-LR (MC-LR) in drinking and surface waters. The concentration of coating antigen was 5 μ/mL, the dilution of monoclonal antibody MC10E7 was 1:3 000, the dilution of enzyme tracer (goat anti-mouse IgG-peroxidase) was 1:3 000, the standard concentration of MC-LR ranged from 0.001 μg/L to 30 μg/L, and o-phenylenediamine was used as substrate. The assay showed high relativity with high performance liquid chromatography (HPLC) with a correlation coefficient of more than 99%. The relative standard deviation was less than 10%, the detection limit was achieved down to 0.01 μg/L and up to 5.1 μg/L. The quantitative detection range was from 0.03 μg/L to 3 μg/L, and the antibody had high specificity for [4-arginine] microcystins. It performed well in spite of the influence of the real samples.
Microcystin-LR detection based on indirect competitive enzyme-linked immunosorbent assay
Abstract Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria, which cause lots of accidents and threatens human health. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was established and used to detect microcystin-LR (MC-LR) in drinking and surface waters. The concentration of coating antigen was 5 μ/mL, the dilution of monoclonal antibody MC10E7 was 1:3 000, the dilution of enzyme tracer (goat anti-mouse IgG-peroxidase) was 1:3 000, the standard concentration of MC-LR ranged from 0.001 μg/L to 30 μg/L, and o-phenylenediamine was used as substrate. The assay showed high relativity with high performance liquid chromatography (HPLC) with a correlation coefficient of more than 99%. The relative standard deviation was less than 10%, the detection limit was achieved down to 0.01 μg/L and up to 5.1 μg/L. The quantitative detection range was from 0.03 μg/L to 3 μg/L, and the antibody had high specificity for [4-arginine] microcystins. It performed well in spite of the influence of the real samples.
Microcystin-LR detection based on indirect competitive enzyme-linked immunosorbent assay
Sheng, Jianwu (Autor:in) / He, Miao (Autor:in) / Yu, Shaoqing (Autor:in) / Shi, Hanchang (Autor:in) / Qian, Yi (Autor:in)
01.07.2007
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Sensitivitas Enzyme Linked Immunosorbent Assay (ELISA) dalam Diagnosis Leptospirosis pada Manusia
British Library Conference Proceedings | 1995
|Enzyme-linked immunosorbent assay (ELISA) for the anthropogenic marker isolithocholic acid in water
Online Contents | 2016
|British Library Online Contents | 2014
|British Library Online Contents | 1998
|