Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Classification of Hardened Cement and Lime Mortar Using Short-Wave Infrared Spectrometry Data
Abstract This paper evaluated the feasibility of using spectrometry data in the short-wave infrared range (1,300–2,200 nm) to distinguish lime mortar and Type S cement mortar using 42 lab samples (21 lime-based, 21 cement-based) each 40×40×40 mm were created. A Partial Least Squares Discriminant Analysis model was developed using the mean spectra of 28 specimens as the calibration set. The results were tested on the mean spectra of the remaining 14 specimens as a validation set. The results showed that, spectrometry data were able to fully distinguish modern mortars (made with cement) from historic lime mortars with a 100% classification accuracy, which can be very useful in archaeological and architectural conservation applications. Specifically, being able to distinguish mortar composition in situ can provide critical information about the construction history of a structure, as well as to inform an appropriate intervention scheme when historic material needs to be repaired or replaced.
Classification of Hardened Cement and Lime Mortar Using Short-Wave Infrared Spectrometry Data
Abstract This paper evaluated the feasibility of using spectrometry data in the short-wave infrared range (1,300–2,200 nm) to distinguish lime mortar and Type S cement mortar using 42 lab samples (21 lime-based, 21 cement-based) each 40×40×40 mm were created. A Partial Least Squares Discriminant Analysis model was developed using the mean spectra of 28 specimens as the calibration set. The results were tested on the mean spectra of the remaining 14 specimens as a validation set. The results showed that, spectrometry data were able to fully distinguish modern mortars (made with cement) from historic lime mortars with a 100% classification accuracy, which can be very useful in archaeological and architectural conservation applications. Specifically, being able to distinguish mortar composition in situ can provide critical information about the construction history of a structure, as well as to inform an appropriate intervention scheme when historic material needs to be repaired or replaced.
Classification of Hardened Cement and Lime Mortar Using Short-Wave Infrared Spectrometry Data
Zahiri, Zohreh (Autor:in) / Laefer, Debra F. (Autor:in) / Gowen, Aoife (Autor:in)
01.01.2019
10 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Engineering Index Backfile | 1891
POLYMER CEMENT COMPOSITION, POLYMER CEMENT MORTAR, AND MORTAR HARDENED BODY
Europäisches Patentamt | 2016
|Engineering Index Backfile | 1890
|Cement mortar vs. lime mortar in building construction
Engineering Index Backfile | 1928
|Lime. Hydraulic cement, mortar and concrete
Engineering Index Backfile | 1897
|