Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Hydro-thermal coupled analysis for health monitoring of embankment dams
Abstract Measuring and analyzing internal dam temperature may provide insight into evaluating the integrity of earthen dams. Temperature in a dam, with the advent of modern distributed temperature sensing (DTS) technique, is conveniently measured. The analysis of the temperature is conducted based on a hydro-thermal coupled analysis technique. In this study, DTS-based temperature data and VS2DHI (a finite difference code for analyzing two-dimensional heat transport in porous media) were used to analyze the hydro-thermal coupled behavior in a dam. The results of this analysis show that the temperature variation in an earthen dam is closely related to seepage conditions. Additionally, a localized high-temperature (26 °C) zone found in the measured data of the dam, which raised concern to engineers on site, is explained through either hot water infiltration into the foundation layer or lower permeability of the foundation layer than the magnitude that appeared in the design document. These findings demonstrate that hydro-thermal coupled analysis has the potential for evaluating the integrity of earthen dams.
Hydro-thermal coupled analysis for health monitoring of embankment dams
Abstract Measuring and analyzing internal dam temperature may provide insight into evaluating the integrity of earthen dams. Temperature in a dam, with the advent of modern distributed temperature sensing (DTS) technique, is conveniently measured. The analysis of the temperature is conducted based on a hydro-thermal coupled analysis technique. In this study, DTS-based temperature data and VS2DHI (a finite difference code for analyzing two-dimensional heat transport in porous media) were used to analyze the hydro-thermal coupled behavior in a dam. The results of this analysis show that the temperature variation in an earthen dam is closely related to seepage conditions. Additionally, a localized high-temperature (26 °C) zone found in the measured data of the dam, which raised concern to engineers on site, is explained through either hot water infiltration into the foundation layer or lower permeability of the foundation layer than the magnitude that appeared in the design document. These findings demonstrate that hydro-thermal coupled analysis has the potential for evaluating the integrity of earthen dams.
Hydro-thermal coupled analysis for health monitoring of embankment dams
Yosef, Tewodros Y. (Autor:in) / Song, Chung R. (Autor:in) / Chang, Ki-Tae (Autor:in)
Acta Geotechnica ; 13 ; 447-455
02.08.2017
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Coupled analysis , Embankment , Health monitoring , Sensor , Temperature data Engineering , Geoengineering, Foundations, Hydraulics , Continuum Mechanics and Mechanics of Materials , Geotechnical Engineering & Applied Earth Sciences , Soil Science & Conservation , Soft and Granular Matter, Complex Fluids and Microfluidics , Structural Mechanics
Hydro-thermal coupled analysis for health monitoring of embankment dams
Online Contents | 2017
|British Library Conference Proceedings | 1995
|Thermal Monitoring of Embankment Dams by Fiber Optics
British Library Conference Proceedings | 2010
|Springer Verlag | 2015
|