Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
The definition of fire resistance requirements for stadium and arena developments based on risk
Abstract In the United Kingdom, as in most other countries, the required fire resistance period of a building is traditionally given by the recommendations of prescriptive documents, such as the Approved Document B, depending on the usage and the height of the building. However, for large developments like stadia and arenas, which involve different usages such as assembly, office and retail facilities in combination with a very large number of people and the significance of this type of structure to the communities, these simple rules given in the prescriptive guidance to fire safety are not applicable. Furthermore, structural fire protection forms a significant part of the cost of a structure and also plays a significant part in the environmental impact and the embodied energy. Therefore, a risk based approach to the fire resistance requirements of large stadia and arenas has been developed and validated in this paper to ensure that the appropriate standard of safety is achieved in the most appropriate and economic manner. The approach allows a detailed assessment of the risk of failure of individual elements of structure and structural systems in a stadium rather than specifying a single fire resistance period for the whole building, which might be overly conservative for some members, but potentially unsafe for critical elements. The approach also allows for investigating the influence of individual parameters such as management, and the fire load. The method ensures that all three risk parameters i.e. frequency, probability, consequence will be assessed for the different structural elements based on available data from similar buildings, calculations and experiences. It could be shown that the proposed method gives consistent and comparable results for office, retail and assembly buildings, if compared with the recommendations given in the British Standard BS9999. It should be noted that the approach is based on the principles of risk; however it is semi-quantitative, and as a result contains some subjectivity. Therefore, it is important that the results are assessed for consistency and that they are logical and explainable.
The definition of fire resistance requirements for stadium and arena developments based on risk
Abstract In the United Kingdom, as in most other countries, the required fire resistance period of a building is traditionally given by the recommendations of prescriptive documents, such as the Approved Document B, depending on the usage and the height of the building. However, for large developments like stadia and arenas, which involve different usages such as assembly, office and retail facilities in combination with a very large number of people and the significance of this type of structure to the communities, these simple rules given in the prescriptive guidance to fire safety are not applicable. Furthermore, structural fire protection forms a significant part of the cost of a structure and also plays a significant part in the environmental impact and the embodied energy. Therefore, a risk based approach to the fire resistance requirements of large stadia and arenas has been developed and validated in this paper to ensure that the appropriate standard of safety is achieved in the most appropriate and economic manner. The approach allows a detailed assessment of the risk of failure of individual elements of structure and structural systems in a stadium rather than specifying a single fire resistance period for the whole building, which might be overly conservative for some members, but potentially unsafe for critical elements. The approach also allows for investigating the influence of individual parameters such as management, and the fire load. The method ensures that all three risk parameters i.e. frequency, probability, consequence will be assessed for the different structural elements based on available data from similar buildings, calculations and experiences. It could be shown that the proposed method gives consistent and comparable results for office, retail and assembly buildings, if compared with the recommendations given in the British Standard BS9999. It should be noted that the approach is based on the principles of risk; however it is semi-quantitative, and as a result contains some subjectivity. Therefore, it is important that the results are assessed for consistency and that they are logical and explainable.
The definition of fire resistance requirements for stadium and arena developments based on risk
Block, Florian M. (Autor:in) / Butterworth, Neal A. (Autor:in)
International Journal of Steel Structures ; 9 ; 39-46
01.03.2009
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
TIBKAT | 2015
|Otkritie Arena: Design of the new Spartak Moscow Stadium
Online Contents | 2014
|Risk-based fire resistance requirements
Tema Archiv | 2005
|The `Arena Auf Schalke' multi-purpose stadium, Gelsenkirchen, Germany
British Library Online Contents | 2002
|Otkritie Arena: Design of the new Spartak Moscow Stadium
Wiley | 2014
|