Performance Evaluation of Retrofitted Exterior Beam Column Joint Under Cyclic Loading
This research paper presents an experimental study on the cyclic behavior of retrofitted exterior beam-column joint using textile reinforced concrete. Exterior beam-column joint specimens were cast and tested under reverse cyclic loading upto a certain drift and then damaged specimens were retrofitted using textile reinforced concrete (TRC). The cover concrete in the cracked regions were removed and TRC has been used at top and bottom of the joint instead of replacing the core concrete. Repaired joints were tested under quasi static loading till it reaches the failure stage. Parameters such as damage tolerance, hysteretic curve, dissipate energy were used to examine the performance of the retrofitting schemes. It shows that the use of TRC as the external strengthening measures works upto a certain extent compared to the conventional joint interms of energy dissipation and stiffness retention.
Performance Evaluation of Retrofitted Exterior Beam Column Joint Under Cyclic Loading
This research paper presents an experimental study on the cyclic behavior of retrofitted exterior beam-column joint using textile reinforced concrete. Exterior beam-column joint specimens were cast and tested under reverse cyclic loading upto a certain drift and then damaged specimens were retrofitted using textile reinforced concrete (TRC). The cover concrete in the cracked regions were removed and TRC has been used at top and bottom of the joint instead of replacing the core concrete. Repaired joints were tested under quasi static loading till it reaches the failure stage. Parameters such as damage tolerance, hysteretic curve, dissipate energy were used to examine the performance of the retrofitting schemes. It shows that the use of TRC as the external strengthening measures works upto a certain extent compared to the conventional joint interms of energy dissipation and stiffness retention.
Performance Evaluation of Retrofitted Exterior Beam Column Joint Under Cyclic Loading
Structural Integrity
Fonseca de Oliveira Correia, José António (Herausgeber:in) / Choudhury, Satyabrata (Herausgeber:in) / Dutta, Subhrajit (Herausgeber:in) / Yadav, Yogesh (Autor:in) / Siva Chidambaram, R. (Autor:in)
International Conference on Advances in Structural Mechanics and Applications ; 2021 ; Silchar, India
Advances in Structural Mechanics and Applications ; Kapitel: 15 ; 180-187
Structural Integrity ; 26
15.07.2022
8 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
CFRP-retrofitted RC exterior beam-column connections under cyclic loads
British Library Conference Proceedings | 2004
|Performance of Exterior RC Beam Column Joint Retrofitted with HP-FRC
Springer Verlag | 2024
|Numerical modelling of CFRP-retrofitted RC exterior beam-column joints under cyclic loads
British Library Conference Proceedings | 2008
|Numerical modelling of CFRP-retrofitted RC exterior beam-column joints under cyclic loads
British Library Conference Proceedings | 2008
|