Heating of electrodes during spot resistance welding in FEM calculations
Due to the fact that many factors influence the electrode life, it is difficult to assess this impact experimentally. The study presents the analysis of the impact of individual factors on the heating of selected electrodes at specific operating parameters. The analysis was based on a SORPAS programme, intended for calculations related to resistance welding, in particular, to spot welding. In selected cases FEM calculations were verified experimentally through measurements of electrode temperature during welding cycles.
The calculations were carried out for 1 + 1 mm and 2 + 2 mm plates made of steel DX52, for hard and soft parameters. The analysis involved various designs of an electrode tip (outer diametersofelectrodesof13,16and20 mmaswellasabevel angleof608and 1208-incaseof electrodes with flat working parts, and an end radius of 50 mm - in case of spherical electrodes). The tests also concerned the impact of the “height” of an electrode working area (i.e. the distance from the cooling duct of 10.5 mm and 3 mm) on temperature distribution in an electrode.
Heating of electrodes during spot resistance welding in FEM calculations
Due to the fact that many factors influence the electrode life, it is difficult to assess this impact experimentally. The study presents the analysis of the impact of individual factors on the heating of selected electrodes at specific operating parameters. The analysis was based on a SORPAS programme, intended for calculations related to resistance welding, in particular, to spot welding. In selected cases FEM calculations were verified experimentally through measurements of electrode temperature during welding cycles.
The calculations were carried out for 1 + 1 mm and 2 + 2 mm plates made of steel DX52, for hard and soft parameters. The analysis involved various designs of an electrode tip (outer diametersofelectrodesof13,16and20 mmaswellasabevel angleof608and 1208-incaseof electrodes with flat working parts, and an end radius of 50 mm - in case of spherical electrodes). The tests also concerned the impact of the “height” of an electrode working area (i.e. the distance from the cooling duct of 10.5 mm and 3 mm) on temperature distribution in an electrode.
Heating of electrodes during spot resistance welding in FEM calculations
Archiv.Civ.Mech.Eng
Mikno, Z. (Autor:in) / Bartnik, Z. (Autor:in)
Archives of Civil and Mechanical Engineering ; 16 ; 86-100
01.03.2016
15 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Heating of electrodes during spot resistance welding in FEM calculations
British Library Online Contents | 2016
|Heating of electrodes during spot resistance welding in FEM calculations
British Library Online Contents | 2016
|Factors affecting deformation of electrodes when resistance spot welding coated steel
British Library Online Contents | 1995
|British Library Online Contents | 2004
|Compact storage-based resistance spot welding power supplies
UB Braunschweig | 2016
|