Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Design roughness coefficients of lined canals for hydroelectric power plants
Conclusions 1. Due to the fact that the roughness of lined canals is not stable, the norms should indicate the values of the design roughness coefficients in accordance with the purpose of the corresponding computation. 2. In elaborating the new norms, it is advisable to reduce the range of possible values of the roughness coefficient for some of the lining types. The indicated measure requires from the contractor a guarantee that certain absolute values of the roughness will not be exceeded. 3. The norms for selecting design roughness coefficients should be the same for all the departments.
Design roughness coefficients of lined canals for hydroelectric power plants
Conclusions 1. Due to the fact that the roughness of lined canals is not stable, the norms should indicate the values of the design roughness coefficients in accordance with the purpose of the corresponding computation. 2. In elaborating the new norms, it is advisable to reduce the range of possible values of the roughness coefficient for some of the lining types. The indicated measure requires from the contractor a guarantee that certain absolute values of the roughness will not be exceeded. 3. The norms for selecting design roughness coefficients should be the same for all the departments.
Design roughness coefficients of lined canals for hydroelectric power plants
Vasil'ev, Yu. S. (Autor:in)
Hydrotechnical Construction ; 1 ; 465-467
01.05.1967
3 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Design roughness coefficients of lined canals for hydroelectric power plants
Online Contents | 1967
|Concrete lined irrigation canals
Engineering Index Backfile | 1920
Simple Design Procedure for Lined Irrigation Canals
British Library Online Contents | 1996
|Alternative to Dredging Concrete-Lined Canals
Online Contents | 1996