Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparison between high strength concrete and normal strength concrete subjected to high temperature
Abstract Two normal strength concretes and three high strength concretes, with 28-day compressive strengths of 28, 47, 76, 79 and 94 MPa respectively, were used to compare the effect of high temperatures on high strength concrete and normal strength concrete. After being heated to a series of maximum temperatures at 400, 600, 800, 1000 and 1200°C, and maintained for 1 hour, their compressive strengths and tensile splitting strengths were determined. The pore size distribution of hardened cement paste in high strength concrete and normal strength concrete was also investigated. Results show that high strength concrete lost its mechanical strength in a manner similar to or slightly better than that of NSC. The range between 400 and 800°C was critical to the strength loss of concrete with a large percentage of loss of strength. Microstructural study carried out revealed that high temperatures have a coarsening effect on the microstructure of both of high strength concrete and normal strength concrete.
Résumé On a comparé l'effet des hautes températures sur deux bétons de résistance ordinaire et trois bétons de haute résistance, ayant des résistances à la compression à 28 jours de 28, 47, 76, 79 et 94 MPa, respectivement. Ces bétons ont été chauffés selon une série de températures maximales de 400, 600, 800, 1 000 et 1 200°C, et maintenus pendant une heure; ensuite, on a déterminé leurs résistances à la compression et leur résistance en traction. On a également étudié la répartition du diamètre des pores des pâtes de ciment durci des bétons de haute résistance et de résistance ordinaire. Les bétons de haute résistance montrent une perte de résistance mécanique similaire, ou légère ment moindre, aux bétons de résistance ordinaire. La gamme des températures entre 400 et 800°C s'est avéré critique en ce qui concerne les plus forts pourcentages de perte de résistance du béton. Une étude de la microstructure a montré que les hautes températures ont pour effet de rendre plus grossière la microstructure des bétons de haute résistance et des bétons de résistance ordinaire.
Comparison between high strength concrete and normal strength concrete subjected to high temperature
Abstract Two normal strength concretes and three high strength concretes, with 28-day compressive strengths of 28, 47, 76, 79 and 94 MPa respectively, were used to compare the effect of high temperatures on high strength concrete and normal strength concrete. After being heated to a series of maximum temperatures at 400, 600, 800, 1000 and 1200°C, and maintained for 1 hour, their compressive strengths and tensile splitting strengths were determined. The pore size distribution of hardened cement paste in high strength concrete and normal strength concrete was also investigated. Results show that high strength concrete lost its mechanical strength in a manner similar to or slightly better than that of NSC. The range between 400 and 800°C was critical to the strength loss of concrete with a large percentage of loss of strength. Microstructural study carried out revealed that high temperatures have a coarsening effect on the microstructure of both of high strength concrete and normal strength concrete.
Résumé On a comparé l'effet des hautes températures sur deux bétons de résistance ordinaire et trois bétons de haute résistance, ayant des résistances à la compression à 28 jours de 28, 47, 76, 79 et 94 MPa, respectivement. Ces bétons ont été chauffés selon une série de températures maximales de 400, 600, 800, 1 000 et 1 200°C, et maintenus pendant une heure; ensuite, on a déterminé leurs résistances à la compression et leur résistance en traction. On a également étudié la répartition du diamètre des pores des pâtes de ciment durci des bétons de haute résistance et de résistance ordinaire. Les bétons de haute résistance montrent une perte de résistance mécanique similaire, ou légère ment moindre, aux bétons de résistance ordinaire. La gamme des températures entre 400 et 800°C s'est avéré critique en ce qui concerne les plus forts pourcentages de perte de résistance du béton. Une étude de la microstructure a montré que les hautes températures ont pour effet de rendre plus grossière la microstructure des bétons de haute résistance et des bétons de résistance ordinaire.
Comparison between high strength concrete and normal strength concrete subjected to high temperature
Chan, Sammy Y. N. (Autor:in) / Peng, Gai-fei (Autor:in) / Chan, John K. W. (Autor:in)
Materials and Structures ; 29 ; 616-619
01.12.1996
4 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Comparison Between High Strength Concrete and Normal Strength Concrete Subjected to High Temperature
British Library Online Contents | 1996
|COMPARISON BETWEEN HIGH STRENGTH CONCRETE AND NORMAL STRENGTH CONCRETE SUBJECTED TO HIGH TEMPERATURE
Online Contents | 1996
|British Library Conference Proceedings | 2008
|Behaviour of High Strength Concrete Subjected to Elevated Temperature
British Library Conference Proceedings | 1999
|