Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Transient behavior of CO2 in the internal heat exchanger during the start-up of the transcritical refrigeration system
Transient behavior of internal heat exchanger during start-up of transcritical refrigeration system is investigated in this article. The work is focused on the local transient analysis of CO2 thermophysical properties, in order to see how these transient changes affect the heat transfer rate and the effectiveness of internal heat exchanger, as well as the coefficient of performance during the start-up of the system. The study is conducted through a numerical simulation using the commercial computational fluid dynamics (CFD) software Ansys Fluent. Validation of numerical results is carried out by using seven different empirical correlations applied for the Nusselt number. It is observed that the thermophysical properties of the hot CO2 stream experience large changes during the transient period. This instability is accompanied by a decrease in the heat transfer rate. Finally, the change in the internal heat exchanger effectiveness during the start-up results in a loss of about 12% of the coefficient of performance.
Transient behavior of CO2 in the internal heat exchanger during the start-up of the transcritical refrigeration system
Transient behavior of internal heat exchanger during start-up of transcritical refrigeration system is investigated in this article. The work is focused on the local transient analysis of CO2 thermophysical properties, in order to see how these transient changes affect the heat transfer rate and the effectiveness of internal heat exchanger, as well as the coefficient of performance during the start-up of the system. The study is conducted through a numerical simulation using the commercial computational fluid dynamics (CFD) software Ansys Fluent. Validation of numerical results is carried out by using seven different empirical correlations applied for the Nusselt number. It is observed that the thermophysical properties of the hot CO2 stream experience large changes during the transient period. This instability is accompanied by a decrease in the heat transfer rate. Finally, the change in the internal heat exchanger effectiveness during the start-up results in a loss of about 12% of the coefficient of performance.
Transient behavior of CO2 in the internal heat exchanger during the start-up of the transcritical refrigeration system
Ituna-Yudonago, Jean F. (Autor:in) / Belman-Flores, Juan Manuel (Autor:in) / Elizalde-Blancas, Francisco (Autor:in) / Serrano-Arellano, Juan (Autor:in) / Pérez-García, Vicente (Autor:in) / Gutiérrez-León, Diana G. (Autor:in)
Science and Technology for the Built Environment ; 23 ; 594-607
19.05.2017
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Contribution of Internal Heat Exchanger to Transcritical R-744 Cycle Performance
Taylor & Francis Verlag | 2001
|Contribution of Internal Heat Exchanger to Transcritical R-744 Cycle Performance
British Library Online Contents | 2001
|Contribution of Internal Heat Exchanger to Transcritical R-744 Cycle Performance
British Library Conference Proceedings | 2001
|Energy analysis of a transcritical CO2 supermarket refrigeration system with heat recovery
BASE | 2017
|Experimental evaluation of transcritical CO2 refrigeration with mechanical subcooling
Taylor & Francis Verlag | 2017
|