Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Methodology to assess “no-touch” building audit software using simulated utility data
Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.
Methodology to assess “no-touch” building audit software using simulated utility data
Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.
Methodology to assess “no-touch” building audit software using simulated utility data
Cheung, Howard (Autor:in) / Langner, M. Rois (Autor:in) / Braun, James E. (Autor:in)
Science and Technology for the Built Environment ; 26 ; 873-887
08.08.2020
15 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
A methodology for a thermal energy building audit
British Library Online Contents | 2004
|A methodology for a thermal energy building audit
Online Contents | 2004
|Advantages of Utility Management Audit
Wiley | 1966
|A method to compare simulated and measured data to assess building energy performance
Online Contents | 2012
|