Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Refinery Evaluation of Optical Imaging to Locate Fugitive Emissions
Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.
Refinery Evaluation of Optical Imaging to Locate Fugitive Emissions
Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.
Refinery Evaluation of Optical Imaging to Locate Fugitive Emissions
Robinson, Donald R. (Autor:in) / Luke-Boone, Ronke (Autor:in) / Aggarwal, Vineet (Autor:in) / Harris, Buzz (Autor:in) / Anderson, Eric (Autor:in) / Ranum, David (Autor:in) / Kulp, Thomas J. (Autor:in) / Armstrong, Karla (Autor:in) / Sommers, Ricky (Autor:in) / McRae, Thomas G. (Autor:in)
Journal of the Air & Waste Management Association ; 57 ; 803-810
01.07.2007
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Direct Measurement of Fugitive Emissions of Hydrocarbons from a Refinery
Taylor & Francis Verlag | 2008
|Evaluation and Applicability of Flame Ionization Detector for Fugitive Emissions
British Library Conference Proceedings | 2014
|Monitoring of fugitive emissions in petrochemical plant
British Library Conference Proceedings | 1994
|British Library Conference Proceedings | 1994
|New techniques developed for measuring fugitive emissions
Online Contents | 1995
|