Comparison of UV and UV/H2O2 treatments using excilamps for removal of monochlorophenols in the molecular and anionic form
The efficiency of UV/H2O2 treatment using KrCl (222 nm) and XeBr (282 nm) excilamps was examined for removal of 2-chlorophenol (2-CP) and 4-chlorophenol (4-CP) from aqueous solution in the molecular form (pH 2 and un-adjusted pH) and anionic form (at pH 11). UV/H2O2 treatment of 2- or 4-CP was initially carried out at un-adjusted pH with varying molar ratios of chlorophenol and H2O2. The para-chlorobenzoic acid was used as a hydroxyl radical (•OH) probe compound. UV/H2O2 treatment of 2- and 4-CP with a molar ratio of 1:25 at ambient pH and a fluence of 4.1 J/cm2 provided a significant decrease in chemical oxygen demand (COD). Under these conditions, the •OH exposure was found to increase from 0.5 × 10−11 and 0.4 × 10−11 to 1.8 × 10−11 and 1.3 × 10−11 M min for KrCl and XeBr excilamp, respectively. Compared with direct UV photolysis, the pseudo-first-order fluence-based rate constants of 2- and 4-CP degradation in UV/H2O2 process at a molar ratio of 1:25 were significantly higher for molecular 2-CP and 4-CP in the anionic form using both excilamps. Detailed information on UV fluence and/or the exposure to •OH radicals is proposed to accurately compare studies reporting the effectiveness of AOPs based on excilamps.
Comparison of UV and UV/H2O2 treatments using excilamps for removal of monochlorophenols in the molecular and anionic form
The efficiency of UV/H2O2 treatment using KrCl (222 nm) and XeBr (282 nm) excilamps was examined for removal of 2-chlorophenol (2-CP) and 4-chlorophenol (4-CP) from aqueous solution in the molecular form (pH 2 and un-adjusted pH) and anionic form (at pH 11). UV/H2O2 treatment of 2- or 4-CP was initially carried out at un-adjusted pH with varying molar ratios of chlorophenol and H2O2. The para-chlorobenzoic acid was used as a hydroxyl radical (•OH) probe compound. UV/H2O2 treatment of 2- and 4-CP with a molar ratio of 1:25 at ambient pH and a fluence of 4.1 J/cm2 provided a significant decrease in chemical oxygen demand (COD). Under these conditions, the •OH exposure was found to increase from 0.5 × 10−11 and 0.4 × 10−11 to 1.8 × 10−11 and 1.3 × 10−11 M min for KrCl and XeBr excilamp, respectively. Compared with direct UV photolysis, the pseudo-first-order fluence-based rate constants of 2- and 4-CP degradation in UV/H2O2 process at a molar ratio of 1:25 were significantly higher for molecular 2-CP and 4-CP in the anionic form using both excilamps. Detailed information on UV fluence and/or the exposure to •OH radicals is proposed to accurately compare studies reporting the effectiveness of AOPs based on excilamps.
Comparison of UV and UV/H2O2 treatments using excilamps for removal of monochlorophenols in the molecular and anionic form
Matafonova, Galina G. (Autor:in) / Batoev, Valeriy B. (Autor:in)
Journal of Environmental Science and Health, Part A ; 47 ; 2077-2083
01.11.2012
7 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Fluorescent Penetrant Testing by Means of Excilamps
British Library Online Contents | 2019
|Biodegradation of phenol and monochlorophenols by yeast Rhodotorula glutinis
British Library Conference Proceedings | 1994
|Effect of electron beam irradiation on the degradation of monochlorophenols in aqueous solution