Removal efficiency of swirl/vortex separators
In this paper an efficiency formula for swirl/vortex separators is proposed. It is based on the combination of scale model tests on a simple vortex separator and literature results from tests on similar devices. The formula predicts the removal efficiency of cylindrical overflow constructions as a function of flow conditions, chamber geometry and particle settling velocity. The formula has furthermore been used to make a comparison with the efficiency of a high-side weir overflow and a storage sedimentation tank.
Removal efficiency of swirl/vortex separators
In this paper an efficiency formula for swirl/vortex separators is proposed. It is based on the combination of scale model tests on a simple vortex separator and literature results from tests on similar devices. The formula predicts the removal efficiency of cylindrical overflow constructions as a function of flow conditions, chamber geometry and particle settling velocity. The formula has furthermore been used to make a comparison with the efficiency of a high-side weir overflow and a storage sedimentation tank.
Removal efficiency of swirl/vortex separators
Luyckx, Gert (Autor:in) / Berlamont, Jean (Autor:in)
Urban Water Journal ; 1 ; 251-260
01.09.2004
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Comparative laboratory study of swirl, vortex and helical bend separators
British Library Conference Proceedings | 1993
|Swirl-Flo[TM] and Lamella Separators - A Comparison
British Library Conference Proceedings | 1995
|Solids removal from combined sewer overflows with vortex separators
British Library Conference Proceedings | 1992
|Practical Applications of Vortex Flow Separators in the Czech Republic
British Library Conference Proceedings | 1995
|High-efficiency separators. Part 2: Optimizing performance
British Library Online Contents | 1995
|