Evaluation of in-situ permeability measurement methods for pervious concrete pavement
The permeability coefficient is the foundation of evaluating the clogging and maintenance. In this study, 384 field tests were carried out on 9 positions using single-ring and double-ring permeameters with different diameters. Both falling head and constant head methods were evaluated. At the same time, core samples were drilled from the 9 test positions, and their permeability coefficients were measured in the laboratory. The results show that there is a good correlation between falling head method and constant head method, both of them can be used to measure in-situ permeability coefficient of pervious pavement. Although the double-ring method can reduce the transverse seepage inside the pavement, the effect of double-ring permeameters with different cylinder diameters is different, and permeameters with larger cylinder diameters are better. For sites with permeability greater than 2 mm/s, it is not recommended to use permeameters with small cylinder diameters..
Evaluation of in-situ permeability measurement methods for pervious concrete pavement
The permeability coefficient is the foundation of evaluating the clogging and maintenance. In this study, 384 field tests were carried out on 9 positions using single-ring and double-ring permeameters with different diameters. Both falling head and constant head methods were evaluated. At the same time, core samples were drilled from the 9 test positions, and their permeability coefficients were measured in the laboratory. The results show that there is a good correlation between falling head method and constant head method, both of them can be used to measure in-situ permeability coefficient of pervious pavement. Although the double-ring method can reduce the transverse seepage inside the pavement, the effect of double-ring permeameters with different cylinder diameters is different, and permeameters with larger cylinder diameters are better. For sites with permeability greater than 2 mm/s, it is not recommended to use permeameters with small cylinder diameters..
Evaluation of in-situ permeability measurement methods for pervious concrete pavement
Zhang, Jiong (Autor:in) / Wang, Zhen (Autor:in) / Xiong, Jingying (Autor:in) / Jin, Qing (Autor:in) / Hou, Deguo (Autor:in) / Song, Zhijun (Autor:in) / Shen, Yong (Autor:in) / Hu, Nian (Autor:in)
Urban Water Journal ; 20 ; 184-192
07.02.2023
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Pervious concrete for pervious pavement and preparation method of pervious concrete
Europäisches Patentamt | 2021
|Pervious concrete admixture and pervious concrete pavement containing same
Europäisches Patentamt | 2024
|British Library Online Contents | 2011
|