Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Lateral Load: Deflection Response of an Embedded Caisson in Marine Clay
The authors refer to the laboratory testing carried out on model caisson embedded in marine clay collected from the Chennai coast in India. The response of lateral load–ground level deflection of caissons under static and cyclic lateral loading is presented and discussed for the varied parameters such as caisson embedment depth ratio (L/D), load eccentricity ratio (e/D), and undrained strength (su) of clay. The results showed that as the caisson L/D increases, the lateral load required to cause a specified ground level deflection increases. At a given lateral load, the deflection levels are increased as the load eccentricity ratio increases from 0.5 to 2.0. As L/D increases from 2 to 3, the increase in the ultimate lateral capacity is found to be 1.8 to 2.0 times. Similarly, for the change in L/D from 3 to 4, this increase in capacity is found to be 1.6 to 1.8 times at all the undrained strength values and e/D values tested. From the cyclic load test results, it was noticed that the deflections mobilized at the cyclic load ratio (CLR = 0.6) were so small and these are hardly 1% to 2% of the diameter of the caisson. A marked increase in the ground level deflection up to about 900 cycles was observed and thereafter the deflection almost remained the same.
Lateral Load: Deflection Response of an Embedded Caisson in Marine Clay
The authors refer to the laboratory testing carried out on model caisson embedded in marine clay collected from the Chennai coast in India. The response of lateral load–ground level deflection of caissons under static and cyclic lateral loading is presented and discussed for the varied parameters such as caisson embedment depth ratio (L/D), load eccentricity ratio (e/D), and undrained strength (su) of clay. The results showed that as the caisson L/D increases, the lateral load required to cause a specified ground level deflection increases. At a given lateral load, the deflection levels are increased as the load eccentricity ratio increases from 0.5 to 2.0. As L/D increases from 2 to 3, the increase in the ultimate lateral capacity is found to be 1.8 to 2.0 times. Similarly, for the change in L/D from 3 to 4, this increase in capacity is found to be 1.6 to 1.8 times at all the undrained strength values and e/D values tested. From the cyclic load test results, it was noticed that the deflections mobilized at the cyclic load ratio (CLR = 0.6) were so small and these are hardly 1% to 2% of the diameter of the caisson. A marked increase in the ground level deflection up to about 900 cycles was observed and thereafter the deflection almost remained the same.
Lateral Load: Deflection Response of an Embedded Caisson in Marine Clay
Kumar, N. Darga (Autor:in) / Rao, S. Narasimha (Autor:in)
Marine Georesources & Geotechnology ; 30 ; 1-31
01.01.2012
31 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Lateral Load: Deflection Response of an Embedded Caisson in Marine Clay
Online Contents | 2012
|Influence of cyclic load on model caisson seawalls embedded in marine clay
British Library Conference Proceedings | 2004
|Studies on Earth Pressures in Model Caisson Embedded in Marine Clay
British Library Conference Proceedings | 2003
|Split type open caisson anti-deflection device and open caisson anti-deflection construction method
Europäisches Patentamt | 2023
|