Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Improvement of variable refrigerant flow system performance using energy saving control strategy and chilled water storage
Variable refrigerant flow system is a popular building air conditioning solution. Modern variable refrigerant flow systems such as multi-functional variable refrigerant flow systems can also provide space cooling, space heating, and water heating to the building simultaneously. The performance improvement of variable refrigerant flow system is a key research topic. In the current article, energy saving potentials of two measures: A new energy saving control strategy and a new variable refrigerant flow system with chilled water storage are theoretically investigated. The energy saving control strategy changed the evaporating temperature based on ambient temperature. The new variable refrigerant flow system utilizes the water storage component in current multi-functional variable refrigerant flow systems as a chilled water storage unit. Simulation is carried out on a validated thermodynamic variable refrigerant flow model in EnergyPlus. The seasonal energy saving potentials of both measures are calculated in four cities: Miami, Houston, Baltimore, and Chicago. The energy saving control strategy can achieve seasonal energy saving as high as 10.8% in cooling season and 15.4% in heating season. The performance of the new system is also compared to baseline variable refrigerant flow system and the seasonal cooling energy saving could reach 12.5%.
Improvement of variable refrigerant flow system performance using energy saving control strategy and chilled water storage
Variable refrigerant flow system is a popular building air conditioning solution. Modern variable refrigerant flow systems such as multi-functional variable refrigerant flow systems can also provide space cooling, space heating, and water heating to the building simultaneously. The performance improvement of variable refrigerant flow system is a key research topic. In the current article, energy saving potentials of two measures: A new energy saving control strategy and a new variable refrigerant flow system with chilled water storage are theoretically investigated. The energy saving control strategy changed the evaporating temperature based on ambient temperature. The new variable refrigerant flow system utilizes the water storage component in current multi-functional variable refrigerant flow systems as a chilled water storage unit. Simulation is carried out on a validated thermodynamic variable refrigerant flow model in EnergyPlus. The seasonal energy saving potentials of both measures are calculated in four cities: Miami, Houston, Baltimore, and Chicago. The energy saving control strategy can achieve seasonal energy saving as high as 10.8% in cooling season and 15.4% in heating season. The performance of the new system is also compared to baseline variable refrigerant flow system and the seasonal cooling energy saving could reach 12.5%.
Improvement of variable refrigerant flow system performance using energy saving control strategy and chilled water storage
Lin, Xiaojie (Autor:in) / Ling, Jiazhen (Autor:in) / Hwang, Yunho (Autor:in) / Radermacher, Reinhard (Autor:in) / Kim, Byungsoon (Autor:in)
Science and Technology for the Built Environment ; 24 ; 483-491
28.05.2018
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Chilled water production: Storage priority control strategy
British Library Online Contents | 1993
|Study on chilled energy storage of air-conditioning system with energy saving
Online Contents | 2014
|Chilled water storage system reduces energy costs
British Library Online Contents | 1993
|Recommissioned Energy Control Strategy for RTE Television Centre's Chilled Water System
DOAJ | 2012
|