Storm sewer pressurization transient – an experimental investigation
Pipe pressurization is examined experimentally by 144 laboratory experiments in a circular tilting pipe between two tanks, in which the transient was triggered by sudden closing of the downstream tank outlet. The experiments cover ranges of values of slope, velocity and filling ratio of the open-channel flow not explored in previous studies. Situations involving considerable air quantity and consequent intense pressure oscillations were also reproduced. Two different pressurization patterns, defined as “smooth” and “abrupt”, were observed, but only the abrupt pattern produced intense pressure oscillations. The comparison among all the abrupt pressurization surges showed how the oscillations changed in starting time, intensity and duration as the pipe slope, the flow rate and the free-surface flow filling ratio varied. The experimental results also stressed the major role of entrapped air in determining the oscillation characteristics, showing that oscillations were actually produced by the pulsating of large air pockets during their migration along the pipe and their release through the upstream manhole.
Storm sewer pressurization transient – an experimental investigation
Pipe pressurization is examined experimentally by 144 laboratory experiments in a circular tilting pipe between two tanks, in which the transient was triggered by sudden closing of the downstream tank outlet. The experiments cover ranges of values of slope, velocity and filling ratio of the open-channel flow not explored in previous studies. Situations involving considerable air quantity and consequent intense pressure oscillations were also reproduced. Two different pressurization patterns, defined as “smooth” and “abrupt”, were observed, but only the abrupt pattern produced intense pressure oscillations. The comparison among all the abrupt pressurization surges showed how the oscillations changed in starting time, intensity and duration as the pipe slope, the flow rate and the free-surface flow filling ratio varied. The experimental results also stressed the major role of entrapped air in determining the oscillation characteristics, showing that oscillations were actually produced by the pulsating of large air pockets during their migration along the pipe and their release through the upstream manhole.
Storm sewer pressurization transient – an experimental investigation
Ferreri, Giovanni B. (Autor:in) / Ciraolo, Giuseppe (Autor:in) / Lo Re, Carlo (Autor:in)
Journal of Hydraulic Research ; 52 ; 666-675
03.09.2014
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Storm sewer pressurization transient - an experimental investigation
British Library Online Contents | 2014
|Experimental Verification of Storm Sewer Transient Flow Simulation
Online Contents | 2014
|Engineering Index Backfile | 1929
|Engineering Index Backfile | 1949
Experimental and numerical investigation of a small scale storm sewer geyser
Taylor & Francis Verlag | 2024
|