Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Building-scale experimental validation of a new model for walls with phase change materials
The current article presents the building-scale experimental validation of a new model for walls equipped with phase change materials. The one-dimensional conduction heat transfer equation is solved using an explicit finite-difference method coupled with an enthalpy method to consider the variable phase change materials thermal capacity. The model is implemented in the transient system simulation tool simulation tool and referred to as Type 3258, and the method used to couple this component to the multi-zone building (known as Type 56) is discussed. The experimental investigation is performed in two identical full-scale test-cells (only one with phase change materials) exposed to the ambient environment. Experimental data are first used to benchmark a transient system simulation tool simulation model of the test-cell without phase change materials. After calibration, the phase change materials model is experimentally validated with data from the phase change materials-equipped test-cell. Compared to the benchmarking procedure (without phase change materials), the root mean square deviation values between the experiments and the simulations (with phase change materials) are lower or in the same order of magnitude. Simulation accurately reproduces the impact of adding phase change materials to the test-cell as observed in the experiments, such as mitigation and time-shift effects. A discussion about computation time concludes the present study.
Building-scale experimental validation of a new model for walls with phase change materials
The current article presents the building-scale experimental validation of a new model for walls equipped with phase change materials. The one-dimensional conduction heat transfer equation is solved using an explicit finite-difference method coupled with an enthalpy method to consider the variable phase change materials thermal capacity. The model is implemented in the transient system simulation tool simulation tool and referred to as Type 3258, and the method used to couple this component to the multi-zone building (known as Type 56) is discussed. The experimental investigation is performed in two identical full-scale test-cells (only one with phase change materials) exposed to the ambient environment. Experimental data are first used to benchmark a transient system simulation tool simulation model of the test-cell without phase change materials. After calibration, the phase change materials model is experimentally validated with data from the phase change materials-equipped test-cell. Compared to the benchmarking procedure (without phase change materials), the root mean square deviation values between the experiments and the simulations (with phase change materials) are lower or in the same order of magnitude. Simulation accurately reproduces the impact of adding phase change materials to the test-cell as observed in the experiments, such as mitigation and time-shift effects. A discussion about computation time concludes the present study.
Building-scale experimental validation of a new model for walls with phase change materials
Delcroix, Benoit (Autor:in) / Kummert, Michaël (Autor:in) / Daoud, Ahmed (Autor:in)
Science and Technology for the Built Environment ; 23 ; 1049-1062
18.08.2017
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Application of Phase Change Materials (PCMs) in Building Walls: A Review
Springer Verlag | 2018
|Phase Change Materials (PCMs) and Their Optimum Position in Building Walls
DOAJ | 2020
|Optimization of passive application of phase-change materials in building walls
British Library Conference Proceedings | 2006
|Taylor & Francis Verlag | 2017
|Numerical model and experimental validation of heat storage with phase change materials
Online Contents | 2007
|