Review and Evaluation of Models Estimating the Minimum Atmospheric Dilution of Gases Exhausted Near Buildings
In this study, eleven mathematical models estimating the minimum possible atmospheric dilution of rooftop exhaust gases around buildings are evaluated and reviewed using data obtained from 72 full-scale tracer tests at two buildings. Quantities measured were the stack height, stack-to-intake distance, stack diameter, wind speed and direction, exhaust flux, and the stack-to-intake dilution. These models are all based on wind-tunnel simulations and are designed to account for a worst-case scenario so that they can be used to provide a conservative safeguard for design of new stacks or for modification purposes. Although none of the models gave outstanding performance relative to the others, Halitsky’s model, derived from the prism tests and Clinical Center data incorporating the exhaust momentum ratio, gave particularly good predictions. Further, all models led to very conservative estimates of the dilution in the case of gases exhausted close to a receptor, suggesting that the models reviewed here should not be used in such cases.
Review and Evaluation of Models Estimating the Minimum Atmospheric Dilution of Gases Exhausted Near Buildings
In this study, eleven mathematical models estimating the minimum possible atmospheric dilution of rooftop exhaust gases around buildings are evaluated and reviewed using data obtained from 72 full-scale tracer tests at two buildings. Quantities measured were the stack height, stack-to-intake distance, stack diameter, wind speed and direction, exhaust flux, and the stack-to-intake dilution. These models are all based on wind-tunnel simulations and are designed to account for a worst-case scenario so that they can be used to provide a conservative safeguard for design of new stacks or for modification purposes. Although none of the models gave outstanding performance relative to the others, Halitsky’s model, derived from the prism tests and Clinical Center data incorporating the exhaust momentum ratio, gave particularly good predictions. Further, all models led to very conservative estimates of the dilution in the case of gases exhausted close to a receptor, suggesting that the models reviewed here should not be used in such cases.
Review and Evaluation of Models Estimating the Minimum Atmospheric Dilution of Gases Exhausted Near Buildings
Georgakis, Kyriakos S. (Autor:in) / Smith, James W. (Autor:in) / Goodfellow, Howard D. (Autor:in) / Pye, John (Autor:in)
Journal of the Air & Waste Management Association ; 45 ; 722-729
01.09.1995
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
British Library Online Contents | 1999
|Calculation of Minimum Available Atmospheric Dilution Downwind of Building Exhausts
British Library Conference Proceedings | 1990
|Models for estimating costs of public buildings maintaining – review and assessment
DOAJ | 2022
|Research of Resource-Exhausted Mining Site Regeneration
British Library Conference Proceedings | 2012
|Effects of model scale in estimating pollutant dispersion near buildings