Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Research on the effect of the refrigerant charge in a variable capacity heat pump
Current energy efficiency regulations have led to the development of heat pumps equipped with variable speed compressors (VSC) and electronic expansion valves (EEV). To reduce the amount of refrigerant charge, heat pump manufacturers are developing units without a liquid receiver. As a result, the amount of refrigerant charge has a direct impact on the unit performance and needs to be optimized. Previous studies have shown the existence of an optimum refrigerant charge that maximizes the COP at a given operating condition. However, with VSC it is not clear if the optimum charge at a given compressor speed is the adequate one at other speed values. This paper analyzes the effects of the refrigerant charge amount on the performance of a brine-to-water heat pump equipped with a VSC and an EEV. For a given compressor speed, the variation of the COP with the charge showed similar trends and an optimum refrigerant charge could be identified. The charge for the maximum COP changes slightly with the compressor speed. The seasonal coefficient of performance (SCOP) is proposed as a better metric for evaluating the optimum charge. Results show that the SCOP is quite stable with the refrigerant charge.
Research on the effect of the refrigerant charge in a variable capacity heat pump
Current energy efficiency regulations have led to the development of heat pumps equipped with variable speed compressors (VSC) and electronic expansion valves (EEV). To reduce the amount of refrigerant charge, heat pump manufacturers are developing units without a liquid receiver. As a result, the amount of refrigerant charge has a direct impact on the unit performance and needs to be optimized. Previous studies have shown the existence of an optimum refrigerant charge that maximizes the COP at a given operating condition. However, with VSC it is not clear if the optimum charge at a given compressor speed is the adequate one at other speed values. This paper analyzes the effects of the refrigerant charge amount on the performance of a brine-to-water heat pump equipped with a VSC and an EEV. For a given compressor speed, the variation of the COP with the charge showed similar trends and an optimum refrigerant charge could be identified. The charge for the maximum COP changes slightly with the compressor speed. The seasonal coefficient of performance (SCOP) is proposed as a better metric for evaluating the optimum charge. Results show that the SCOP is quite stable with the refrigerant charge.
Research on the effect of the refrigerant charge in a variable capacity heat pump
Ortega, Ignacio (Autor:in) / Sieres, Jaime (Autor:in) / Cerdeira, Fernando (Autor:in) / Álvarez, Estrella (Autor:in) / Santos, José Manuel (Autor:in)
Science and Technology for the Built Environment ; 30 ; 611-625
02.07.2024
15 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Variable Refrigerant Flow: An Emerging Air Conditioner and Heat Pump Technology
British Library Conference Proceedings | 2008
|Measured Effect of Air Flow and Refrigerant Charge on a High-Performance Heat Pump
British Library Conference Proceedings | 2008
|Development of variable refrigerant flow heat-pump model for annual-energy simulation
Taylor & Francis Verlag | 2021
|Measured Effect of Air Flow and Refrigerant Charge on Heat Pump Performance in Heating Mode
British Library Conference Proceedings | 2006
|DA-13-026 A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus
British Library Conference Proceedings | 2013
|