Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Modelica-Based Dynamic Modeling of a Chilled-Water Cooling Coil
For heating, ventilating, and air-conditioning (HVAC) systems for commercial buildings, the cooling coils in air-handling units (AHUs) account for a significant fraction of total building energy consumption and have a major impact on comfort conditions and maintenance costs. Development of cost-effective advanced control strategies will enhance the performance and efficiency of AHUs. The control design process can be greatly facilitated with simulation on a high-fidelity dynamic model prior to experimental validation and implementation. This paper presents a dynamic model for a chilled-water cooling coil. The model development was based on Dymola and Air Conditioning Library with some revision on heat exchanger modeling. For chilled-water cooling coil modeling, the major challenges include the variation of coil surface conditions under flow rate changes and partially-dry-partially-wet operations. This study proposes a dynamic coil model that is capable of predicting cooling performances under fully dry, partially-dry-partially-wet, and fully wet conditions. Validation with experimental data from a benchmark study was conducted under both dry and wet surface conditions. The model predicted the experimental results quite well for both transient and steady-state behaviors. Such a transient model will lay a more quality foundation for controller validation at the simulation phase.
Modelica-Based Dynamic Modeling of a Chilled-Water Cooling Coil
For heating, ventilating, and air-conditioning (HVAC) systems for commercial buildings, the cooling coils in air-handling units (AHUs) account for a significant fraction of total building energy consumption and have a major impact on comfort conditions and maintenance costs. Development of cost-effective advanced control strategies will enhance the performance and efficiency of AHUs. The control design process can be greatly facilitated with simulation on a high-fidelity dynamic model prior to experimental validation and implementation. This paper presents a dynamic model for a chilled-water cooling coil. The model development was based on Dymola and Air Conditioning Library with some revision on heat exchanger modeling. For chilled-water cooling coil modeling, the major challenges include the variation of coil surface conditions under flow rate changes and partially-dry-partially-wet operations. This study proposes a dynamic coil model that is capable of predicting cooling performances under fully dry, partially-dry-partially-wet, and fully wet conditions. Validation with experimental data from a benchmark study was conducted under both dry and wet surface conditions. The model predicted the experimental results quite well for both transient and steady-state behaviors. Such a transient model will lay a more quality foundation for controller validation at the simulation phase.
Modelica-Based Dynamic Modeling of a Chilled-Water Cooling Coil
Li, Pengfei (Autor:in) / Li, Yaoyu (Autor:in) / Seem, John E. (Autor:in)
HVAC&R Research ; 16 ; 35-58
01.01.2010
24 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Simulations of Chilled Water Cooling Coil Delta-T Characteristics
British Library Conference Proceedings | 2012
|Simulations of Chilled Water Cooling Coil Delta-T Characteristics
British Library Online Contents | 2012
|Cooling the I=B=R research home with a chilled-water, fan-coil system
UB Braunschweig | 1958
|Chilled Water Coil Freeze Protection via Internal Drying
British Library Online Contents | 1997
|