Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental Study of the Flow of R-134a Through an Adiabatic Helically Coiled Capillary Tube
An experimental investigation was carried out to evaluate the flow characteristics of refrigerant R-134a through an adiabatic helically coiled capillary tube. The effect of various physical parameters like diameter and length of capillary tube, coil pitch, and inlet subcooling on the mass flow rate of R-134a was investigated. Moreover, the refrigerant mass flow rate through an instrumented capillary tube was also compared to that through a noninstrumented capillary tube. It was found that the provision of taps for pressure measurement on the capillary tube surface has a negligible effect on the mass flow rate of R-134a. Further, the coil pitch had a significant effect on the performance of the adiabatic helically coiled capillary tube. It was established that the coil pitch significantly influenced the mass flow rate through the adiabatic helically coiled capillary tube. It was concluded that the effect of coiling of the capillary tube reduces the mass flow rate by 5% to 15%, as compared to those of the straight capillary tube operating under similar conditions. The data obtained from the experiments were analyzed, and a semi-empirical correlation was developed. Almost 97% of the mass flow rate predicted by the proposed correlation lies in the error band of ±10%.
Experimental Study of the Flow of R-134a Through an Adiabatic Helically Coiled Capillary Tube
An experimental investigation was carried out to evaluate the flow characteristics of refrigerant R-134a through an adiabatic helically coiled capillary tube. The effect of various physical parameters like diameter and length of capillary tube, coil pitch, and inlet subcooling on the mass flow rate of R-134a was investigated. Moreover, the refrigerant mass flow rate through an instrumented capillary tube was also compared to that through a noninstrumented capillary tube. It was found that the provision of taps for pressure measurement on the capillary tube surface has a negligible effect on the mass flow rate of R-134a. Further, the coil pitch had a significant effect on the performance of the adiabatic helically coiled capillary tube. It was established that the coil pitch significantly influenced the mass flow rate through the adiabatic helically coiled capillary tube. It was concluded that the effect of coiling of the capillary tube reduces the mass flow rate by 5% to 15%, as compared to those of the straight capillary tube operating under similar conditions. The data obtained from the experiments were analyzed, and a semi-empirical correlation was developed. Almost 97% of the mass flow rate predicted by the proposed correlation lies in the error band of ±10%.
Experimental Study of the Flow of R-134a Through an Adiabatic Helically Coiled Capillary Tube
Khan, Mohd. Kaleem (Autor:in) / Kumar, Ravi (Autor:in) / Sahoo, Pradeep K. (Autor:in)
HVAC&R Research ; 14 ; 749-762
01.09.2008
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Study of helically coiled adiabatic capillary tubes for transcritical CO2 expansion
Oxford University Press | 2013
|British Library Online Contents | 2007
|Experimental Investigation on Flow Characteristics of Supercritical CO~2 in a Helically Coiled Tube
British Library Conference Proceedings | 2013
|British Library Online Contents | 2009
|British Library Conference Proceedings | 2009
|