Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Evaluating the performance of Diagnostic Agent for Building Operation (DABO) and HVAC-Cx tools using the Virtual Cybernetic Building Testbed
Automated commissioning tools are designed to facilitate the commissioning process, thereby decreasing the time and the skill level required to carry out necessary quality control measures. As a result, they enable more thorough testing of building HVAC systems to improve occupant comfort and the persistence of correct system operation. As a part of the International Energy Agency's Annex 47 research project, two tools were developed to perform automated commissioning: (1) the Diagnostic Agent for Building Operation (DABO) tool, developed by Natural Resources Canada, and (2) the heating ventilating and air-conditioning (HVAC) system commissioning tool, HVAC-Cx, developed by the U.S. National Institute of Standards and Technology. This article investigates the performance of these automated commissioning tools for the ongoing commissioning of air-handling units using data from the U.S. National Institute of Standards and Technology Virtual Cybernetic Building Testbed as a means to conduct a repeatable evaluation over a range of operating conditions.
Evaluating the performance of Diagnostic Agent for Building Operation (DABO) and HVAC-Cx tools using the Virtual Cybernetic Building Testbed
Automated commissioning tools are designed to facilitate the commissioning process, thereby decreasing the time and the skill level required to carry out necessary quality control measures. As a result, they enable more thorough testing of building HVAC systems to improve occupant comfort and the persistence of correct system operation. As a part of the International Energy Agency's Annex 47 research project, two tools were developed to perform automated commissioning: (1) the Diagnostic Agent for Building Operation (DABO) tool, developed by Natural Resources Canada, and (2) the heating ventilating and air-conditioning (HVAC) system commissioning tool, HVAC-Cx, developed by the U.S. National Institute of Standards and Technology. This article investigates the performance of these automated commissioning tools for the ongoing commissioning of air-handling units using data from the U.S. National Institute of Standards and Technology Virtual Cybernetic Building Testbed as a means to conduct a repeatable evaluation over a range of operating conditions.
Evaluating the performance of Diagnostic Agent for Building Operation (DABO) and HVAC-Cx tools using the Virtual Cybernetic Building Testbed
Ferretti, Natascha Milesi (Autor:in) / Galler, Michael A. (Autor:in) / Bushby, Steven T. (Autor:in) / Choinière, Daniel (Autor:in)
Science and Technology for the Built Environment ; 21 ; 1154-1164
17.11.2015
11 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
OR-10-006 The Virtual Cybernetic Building Testbed-A Building Emulator
British Library Conference Proceedings | 2010
|OR-10-006 The Virtual Cybernetic Building Testbed-A Building Emulator
British Library Online Contents | 2010
|OR-10-006 The Virtual Cybernetic Building Testbed-A Building Emulator
British Library Online Contents | 2010