Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
A Multiple Load Aggregation Algorithm for Annual Hourly Simulations of GCHP Systems
This article presents a technique to aggregate heating/cooling loads when using the cylindrical heat source method (CHS) to perform annual hourly energy simulations of ground-coupled heat pump (GCHP) systems. The technique, referred to as “multiple load aggregation algorithm” (or MLAA), uses two major thermal history periods, referred to as “past” and “immediate.” In addition, the MLAA accounts for thermal interference among boreholes by numerically solving the two-dimensional temperature field in the borefield. Results of a comparison between the MLAA and the duct storage (DST) model are presented. Several cases are examined with two different borefields and several load profiles. Results obtained for one- and ten-year simulations show that the MLAA is in very good agreement with the DST model. In the worst case, the maximum difference in fluid temperature is of the order of 2 K (3.6°F). This level of precision is more than adequate to perform accurate hourly simulations of GCHP systems.
A Multiple Load Aggregation Algorithm for Annual Hourly Simulations of GCHP Systems
This article presents a technique to aggregate heating/cooling loads when using the cylindrical heat source method (CHS) to perform annual hourly energy simulations of ground-coupled heat pump (GCHP) systems. The technique, referred to as “multiple load aggregation algorithm” (or MLAA), uses two major thermal history periods, referred to as “past” and “immediate.” In addition, the MLAA accounts for thermal interference among boreholes by numerically solving the two-dimensional temperature field in the borefield. Results of a comparison between the MLAA and the duct storage (DST) model are presented. Several cases are examined with two different borefields and several load profiles. Results obtained for one- and ten-year simulations show that the MLAA is in very good agreement with the DST model. In the worst case, the maximum difference in fluid temperature is of the order of 2 K (3.6°F). This level of precision is more than adequate to perform accurate hourly simulations of GCHP systems.
A Multiple Load Aggregation Algorithm for Annual Hourly Simulations of GCHP Systems
Bernier, Michel A. (Autor:in) / Pinel, Patrice (Autor:in) / Labib, Richard (Autor:in) / Paillot, Raphaël (Autor:in)
HVAC&R Research ; 10 ; 471-487
01.10.2004
17 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
A Systemic Simulation Model and Experiments on Vertical Ground Heat Exchangers in GCHP Systems
British Library Conference Proceedings | 2005
|An experimental investigation on ground heat flow balance issue for a GCHP
Oxford University Press | 2011
|Can Hourly-Based Annual Daylighting Simulations Predict Daylight Availability in Dynamic Sky?
BASE | 2019
|Can Hourly-Based Annual Daylighting Simulations Predict Daylight Availability in Dynamic Sky?
BASE | 2019
|A Method for Deriving an Empirical Hourly Base Load Shape from Utility Hourly Total Load Records
British Library Conference Proceedings | 2008
|