Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Static split duct roof ventilators
Split-duct roof ventilators or windcatchers are used to provide both supply and extract ventilation to the spaces which they serve. However, buildings are often erected in conditions where there is no prevailing wind direction. An investigation into four and six segment windcatchers to determine their relative performances under different wind conditions was undertaken usind scale models in a wind tunnel. Conclusions indiciate that six segment windcatchers have a more predictable, reliable performance in uncertain or variablewind conditions. However, a four segment windcatcher that is orientated 45 degrees to the prevailing wind will generate the highest pressure differences and consequently the highest duct speeds in an installation. Further work on strategies for windless conditions are summarized, and scope for further research is indicated. On utilise des ventilateurs de toit a fentes ou des capteurs de vent dans le but a la fois d'alimenter et d'evacuer l'air des locaux pour lesquels ils sont prevus. Cependant, les batiments sont souvent eriges dans des conditions ou il n'y a aucune direction de vent dominante. Des recherches ont ete menees en soufflerie sur des capteurs de vent a quatre et a six segments afin de determiner leur fonctionnement relatif dans des conditions de vent differentes en se servant de maquettes en soufflerie. Les conclusions indiquent que les capteurs de vent a six segments ont des performances plus previsibles et fiables dans des conditions de vent incertaines ou variables. Cependant, les ventilateurs a quatre segments orientes a 45 degres par rapport au vent dominant, produiront la difference de pression la plus haute et par consequent les vitesses de transmission les plus elevees dans une installation.
Static split duct roof ventilators
Split-duct roof ventilators or windcatchers are used to provide both supply and extract ventilation to the spaces which they serve. However, buildings are often erected in conditions where there is no prevailing wind direction. An investigation into four and six segment windcatchers to determine their relative performances under different wind conditions was undertaken usind scale models in a wind tunnel. Conclusions indiciate that six segment windcatchers have a more predictable, reliable performance in uncertain or variablewind conditions. However, a four segment windcatcher that is orientated 45 degrees to the prevailing wind will generate the highest pressure differences and consequently the highest duct speeds in an installation. Further work on strategies for windless conditions are summarized, and scope for further research is indicated. On utilise des ventilateurs de toit a fentes ou des capteurs de vent dans le but a la fois d'alimenter et d'evacuer l'air des locaux pour lesquels ils sont prevus. Cependant, les batiments sont souvent eriges dans des conditions ou il n'y a aucune direction de vent dominante. Des recherches ont ete menees en soufflerie sur des capteurs de vent a quatre et a six segments afin de determiner leur fonctionnement relatif dans des conditions de vent differentes en se servant de maquettes en soufflerie. Les conclusions indiquent que les capteurs de vent a six segments ont des performances plus previsibles et fiables dans des conditions de vent incertaines ou variables. Cependant, les ventilateurs a quatre segments orientes a 45 degres par rapport au vent dominant, produiront la difference de pression la plus haute et par consequent les vitesses de transmission les plus elevees dans une installation.
Static split duct roof ventilators
Gage, S. A. (Autor:in) / Graham, J. M. R. (Autor:in)
Building Research & Information ; 28 ; 234-244
01.07.2000
11 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Static split duct roof ventilators
Online Contents | 2000
|Static split duct roof ventilators
British Library Online Contents | 2000
|Engineering Index Backfile | 1946
|Engineering Index Backfile | 1963
|Comparative tests of roof ventilators
Engineering Index Backfile | 1923
|