Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
This paper presents a load capacity rating procedure and the results of field tests conducted on the Arlington Curved Steel Box Girder Bridge. Two Florida Department of Transportation (FDOT) test trucks with a total weight of up to 117 tons provided the static loading. One FDOT test truck with a total weight of 52.7 tons applied the dynamic loading. The actual behavior of the bridge was ascertained by comparing the field test results with those obtained from three different theoretical mechanical models. Analysis demonstrates how the actual mechanical behavior and load capacity of a curved steel box girder bridge can be well predicted by a proper finite element method based upon as-built bridge plans. Some important parameters, such as impact factors, the effective width of the concrete slab, as well as the structural effect of barriers, are discussed. Finally, the load rating factors for a variety of Florida rating vehicles were determined based on a finite element model generated from field test results and analytical modeling of the bridge. The current capacity ratings are approximately 17 % to 27 % higher than those determined in 1988 using a conventional analytical method. The capacity increase is due mostly to the conservativeness of traditional methods and codes. The research results are instructive and applicable to bridge design and bridge load rating.
This paper presents a load capacity rating procedure and the results of field tests conducted on the Arlington Curved Steel Box Girder Bridge. Two Florida Department of Transportation (FDOT) test trucks with a total weight of up to 117 tons provided the static loading. One FDOT test truck with a total weight of 52.7 tons applied the dynamic loading. The actual behavior of the bridge was ascertained by comparing the field test results with those obtained from three different theoretical mechanical models. Analysis demonstrates how the actual mechanical behavior and load capacity of a curved steel box girder bridge can be well predicted by a proper finite element method based upon as-built bridge plans. Some important parameters, such as impact factors, the effective width of the concrete slab, as well as the structural effect of barriers, are discussed. Finally, the load rating factors for a variety of Florida rating vehicles were determined based on a finite element model generated from field test results and analytical modeling of the bridge. The current capacity ratings are approximately 17 % to 27 % higher than those determined in 1988 using a conventional analytical method. The capacity increase is due mostly to the conservativeness of traditional methods and codes. The research results are instructive and applicable to bridge design and bridge load rating.
Field test and rating of Arlington Curved Steel Box Girder Bridge
Feldversuch und Beurteilung der Arlington Curved Steel Box Girder Bridge
Huang, D. (Autor:in)
2004
23 Seiten, 11 Bilder, 4 Tabellen, 20 Quellen
Aufsatz (Konferenz)
Datenträger
Englisch
Field Test and Rating of Arlington Curved-Steel Box-Girder Bridge: Jacksonville, Florida
British Library Online Contents | 2004
|Field Test of A Curved Steel Box Girder Bridge
ASCE | 2004
|British Library Online Contents | 2010
|Steel girder bridge field test procedures
British Library Online Contents | 1999
|Steel girder bridge field test procedures