A quantitative study of concrete-embedded steel corrosion using potentiostatic pulses
The corrosion rate of steel in reinforced concrete structures may be estimated from the potential decay curve after a pulse interruption, provided that the steel surface area intervening in the measurements is known. Considering that the time constant (r) of the corrosion process is independent of the surface area, it is also possible to determine the corrosion rate from direct measurements oft without the need to know the rebar surface area, provided that the double-layer capacitance value is previously known or a reasonable value of this variable is assumed. The method may also be applied in realsized structures, using small, easy-to-use counter electrodes. Experiments have been performed using small mortar specimens (8.0 cm by 5.5 cm by 2.0 cm) and larger-sized slabs (90 cm by 65 cm by 10 cm) simulating real structures. Rebars were embedded in concrete with and without additives (chlorides and nitrites) and with a cement/sand/water ratio of 1/3/0.5. The reliability of the data obtained is comparable to that of generally accepted conventional electrochemical procedures for measuring linear polarization resistance.
A quantitative study of concrete-embedded steel corrosion using potentiostatic pulses
The corrosion rate of steel in reinforced concrete structures may be estimated from the potential decay curve after a pulse interruption, provided that the steel surface area intervening in the measurements is known. Considering that the time constant (r) of the corrosion process is independent of the surface area, it is also possible to determine the corrosion rate from direct measurements oft without the need to know the rebar surface area, provided that the double-layer capacitance value is previously known or a reasonable value of this variable is assumed. The method may also be applied in realsized structures, using small, easy-to-use counter electrodes. Experiments have been performed using small mortar specimens (8.0 cm by 5.5 cm by 2.0 cm) and larger-sized slabs (90 cm by 65 cm by 10 cm) simulating real structures. Rebars were embedded in concrete with and without additives (chlorides and nitrites) and with a cement/sand/water ratio of 1/3/0.5. The reliability of the data obtained is comparable to that of generally accepted conventional electrochemical procedures for measuring linear polarization resistance.
A quantitative study of concrete-embedded steel corrosion using potentiostatic pulses
Eine quantitative Korrosionsprüfung von in Beton eingebettetem Stahl mit Hilfe potentiostatischer Impulse
Bastidas, D.M. (Autor:in) / Gonzalez, J.A. (Autor:in) / Feliu, S. (Autor:in) / Cobo, A. (Autor:in) / Miranda, J.M. (Autor:in)
Corrosion, Houston ; 63 ; 1094-1100
2007
7 Seiten, 6 Bilder, 2 Tabellen, 28 Quellen
Aufsatz (Zeitschrift)
Englisch
A Quantitative Study of Concrete-Embedded Steel Corrosion Using Potentiostatic Pulses
British Library Online Contents | 2007
|Potentiostatic study of reinforcing steel embedded in chloride contaminated concrete
British Library Conference Proceedings | 2006
|Steel Bar Corrosion Monitoring by Potentiostatic Pulse Method
British Library Conference Proceedings | 2011
|The analysis of potentiostatic transients applied to the corrosion of steel in concrete
British Library Online Contents | 1997
|