Ultrasonic array inspection of the Clifton Suspension Bridge chain-links
Wrought iron chain-links from the Clifton Suspension Bridge have been inspected for fatigue cracking. The inspection uses a 64-element 2 MHz linear ultrasonic array probe. A shoe is used to transmit ultrasound from the array, through the curved surface of the chain-links and into the inspection region. The full-matrix of transmit-receive time domain signals is captured from the array and stored on a computer for off-line post-processing. This approach allows like-for-like comparison of different imaging algorithms, including standard imaging algorithms such as plane and focused B-scans and sector-scans. Images are also obtained using the total focusing method (TFM) which synthetically focuses the beam on each pixel in the image and offers high spatial resolution throughout the imaging plane. The full aperture focusing techniques are shown to perform best on a geometrically identical replica. For example, relative to the slot tip reflection, the background grain noise was at -11.0 dB for the focused sector-scan and -13.1 dB for the TFM. Typical in-situ images obtained from the Clifton Suspension Bridge are then described.
Ultrasonic array inspection of the Clifton Suspension Bridge chain-links
Wrought iron chain-links from the Clifton Suspension Bridge have been inspected for fatigue cracking. The inspection uses a 64-element 2 MHz linear ultrasonic array probe. A shoe is used to transmit ultrasound from the array, through the curved surface of the chain-links and into the inspection region. The full-matrix of transmit-receive time domain signals is captured from the array and stored on a computer for off-line post-processing. This approach allows like-for-like comparison of different imaging algorithms, including standard imaging algorithms such as plane and focused B-scans and sector-scans. Images are also obtained using the total focusing method (TFM) which synthetically focuses the beam on each pixel in the image and offers high spatial resolution throughout the imaging plane. The full aperture focusing techniques are shown to perform best on a geometrically identical replica. For example, relative to the slot tip reflection, the background grain noise was at -11.0 dB for the focused sector-scan and -13.1 dB for the TFM. Typical in-situ images obtained from the Clifton Suspension Bridge are then described.
Ultrasonic array inspection of the Clifton Suspension Bridge chain-links
Prüfung der Kettenglieder der Clifton Hängebrücke mit Ultraschallgruppenstrahler
Drinkwater, B.W. (Autor:in) / Bowler, A.I. (Autor:in)
Insight ; 51 ; 491-498
2009
8 Seiten, 10 Bilder, 3 Tabellen, 12 Quellen
Aufsatz (Zeitschrift)
Englisch
Analysis of Clifton Suspension Bridge
ASCE | 2000
|Analysis of Clifton Suspension Bridge
British Library Conference Proceedings | 2000
|Notes on the clifton suspension bridge
Engineering Index Backfile | 1917
|Clifton Suspension Bridge : an illustrated history
TIBKAT | 1976
|Clifton Suspension Bridge gives up its secrets
British Library Online Contents | 2003