Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Energy implications of filtration in residential and light-commercial buildings
Higher-efficiency HVAC (Heating, Ventilating, Air-Conditioning) filters generally have a higher pressure drop and are widely assumed to increase energy consumption in smaller air conditioning systems. To explore the effects of filters in real buildings, we monitored 17 residential and light-commercial forced air cooling systems in Austin, TX. Measurements were made once per month for one year at each site with filters from three different MERV (Minimum Efficiency Reporting Value) range categories. Measured parameters included system airflow, fan power draw, outdoor unit power draw, cooling capacity, pressure drops across filters and coils, and duct leakage. Higher-efficiency (MER V11-12) filters generally had a small impact on parameters related to cooling energy consumption in the residential and light-commercial test systems when compared to lower-efficiency (MERV2) filters. The median energy consequence of higher-efficiency filtration in the test systems was estimated as a decrease of approximately 16 kWh per ton of nominal capacity (4.6 kWh per kW) per month of cooling season operation, albeit with large variation, with most of these small savings coming from fan energy reductions. These results suggest a weak link between higher-efficiency filters and energy use in residential and light-commercial systems and that other factors should govern filter selection.
Energy implications of filtration in residential and light-commercial buildings
Higher-efficiency HVAC (Heating, Ventilating, Air-Conditioning) filters generally have a higher pressure drop and are widely assumed to increase energy consumption in smaller air conditioning systems. To explore the effects of filters in real buildings, we monitored 17 residential and light-commercial forced air cooling systems in Austin, TX. Measurements were made once per month for one year at each site with filters from three different MERV (Minimum Efficiency Reporting Value) range categories. Measured parameters included system airflow, fan power draw, outdoor unit power draw, cooling capacity, pressure drops across filters and coils, and duct leakage. Higher-efficiency (MER V11-12) filters generally had a small impact on parameters related to cooling energy consumption in the residential and light-commercial test systems when compared to lower-efficiency (MERV2) filters. The median energy consequence of higher-efficiency filtration in the test systems was estimated as a decrease of approximately 16 kWh per ton of nominal capacity (4.6 kWh per kW) per month of cooling season operation, albeit with large variation, with most of these small savings coming from fan energy reductions. These results suggest a weak link between higher-efficiency filters and energy use in residential and light-commercial systems and that other factors should govern filter selection.
Energy implications of filtration in residential and light-commercial buildings
Energieimplikationen der Filtration in Wohn- und Leichtbaugeschäftsgebäuden
Stephens, Brent (Autor:in) / Siegel, Jeffrey A. (Autor:in) / Novoselac, Atila (Autor:in)
2010
12 Seiten, 2 Bilder, 6 Tabellen, 15 Quellen
Aufsatz (Konferenz)
Englisch
Wohngebäude , Heizung , Lüftung , Klimatisierung , Filter , Druckabfall , Energieverbrauch , Monitoring , Luftkühlung , Messung , Luftstrom , Gebläse
OR-10-038 Energy Implications of Filtration in Residential and Light-Commercial Buildings (RP-1299)
British Library Conference Proceedings | 2010
|OR-10-038 Energy Implications of Filtration in Residential and Light-Commercial Buildings (RP-1299)
British Library Online Contents | 2010
|Energy conservation in commercial unad residential buildings
TIBKAT | 1982
|