Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes
A method for determining the original mix composition of hardened slag-blended cement-based materials based on analysis of backscattered electron images combined with loss on ignition measurements is presented. The method does not require comparison to reference standards or prior knowledge of the composition of the binders used. Therefore, it is well-suited for application to real structures. The method is also able to calculate the degrees of reaction of slag and cement. Results obtained from an experimental study involving sixty samples with a wide range of water/binder (w/b) ratios (0.30 to 0.50), slag/binder ratios (0 to 0.6) and curing ages (3 days to 1 year) show that the method is very promising. The mean absolute errors for the estimated slag, water and cement contents (kg/m3), w/b and s/b ratios were 9.1%, 1.5%, 2.5%, 4.7% and 8.7%, respectively. 91% of the estimated w/b ratios were within 0.036 of the actual values.
Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes
A method for determining the original mix composition of hardened slag-blended cement-based materials based on analysis of backscattered electron images combined with loss on ignition measurements is presented. The method does not require comparison to reference standards or prior knowledge of the composition of the binders used. Therefore, it is well-suited for application to real structures. The method is also able to calculate the degrees of reaction of slag and cement. Results obtained from an experimental study involving sixty samples with a wide range of water/binder (w/b) ratios (0.30 to 0.50), slag/binder ratios (0 to 0.6) and curing ages (3 days to 1 year) show that the method is very promising. The mean absolute errors for the estimated slag, water and cement contents (kg/m3), w/b and s/b ratios were 9.1%, 1.5%, 2.5%, 4.7% and 8.7%, respectively. 91% of the estimated w/b ratios were within 0.036 of the actual values.
Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes
Bestimmung des Schlackenanteils, Wasser/Bindemittel-Verhältnisses und Hydratationsgrad in gehärteten Zementpasten
Yio, M.H.N. (Autor:in) / Phelan, J.C. (Autor:in) / Wong, H.S. (Autor:in) / Buenfeld, N.R. (Autor:in)
Cement and Concrete Research ; 56 ; 171-181
2014
11 Seiten, 38 Quellen
Aufsatz (Zeitschrift)
Englisch
Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes
Online Contents | 2014
|Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes
British Library Online Contents | 2014
|Hydration and pore structure characteristic of superplasticized hardened slag cement pastes
British Library Online Contents | 2002
|Influence of slag content and water-binder ratio on leaching behavior of cement pastes
Online Contents | 2016
|