The Experimental Study on the Fire Suppression Effectiveness of Water Mist with the FeCl2 Additives
This paper presents an experimental study of fire suppression effectiveness with water mist containing FeCl2 additives. The investigation focuses on suppression effectiveness under various FeCl2 additives concentrations, working pressures and nozzle different height above the fire source. The experimental results show that: there is a significant impact on fire suppression effectiveness when adding FeCl2 to water mist. There is an optimum additive concentration of extinguishing fire, corresponding to the shortest extinguishing time, the least amount of water, the highest efficiency of extinguishing fire. The nozzle working pressures and nozzle position have effect on the performance of the water mist extinguishing: the greater the pressure is, the shorter water mist fire extinguishing time is. Under the same experimental conditions, the closer the water mist nozzles are to the oil pan, the shorter extinguishing time is.
The Experimental Study on the Fire Suppression Effectiveness of Water Mist with the FeCl2 Additives
This paper presents an experimental study of fire suppression effectiveness with water mist containing FeCl2 additives. The investigation focuses on suppression effectiveness under various FeCl2 additives concentrations, working pressures and nozzle different height above the fire source. The experimental results show that: there is a significant impact on fire suppression effectiveness when adding FeCl2 to water mist. There is an optimum additive concentration of extinguishing fire, corresponding to the shortest extinguishing time, the least amount of water, the highest efficiency of extinguishing fire. The nozzle working pressures and nozzle position have effect on the performance of the water mist extinguishing: the greater the pressure is, the shorter water mist fire extinguishing time is. Under the same experimental conditions, the closer the water mist nozzles are to the oil pan, the shorter extinguishing time is.
The Experimental Study on the Fire Suppression Effectiveness of Water Mist with the FeCl2 Additives
Jian, Chen (Autor:in) / Ying, Xu-Yan (Autor:in) / Na, Wang (Autor:in)
2013
4 Seiten
Aufsatz (Konferenz)
Englisch
The Experimental Study on the Fire Suppression Effectiveness of Water Mist with the FeCl~2 Additives
British Library Conference Proceedings | 2013
|Improving fire suppression of water mist by chemical additives
Tema Archiv | 2007
|Evaluation and Optimization of the Additives on the Fire Suppression Effectiveness of Water Mist
British Library Conference Proceedings | 2005
|Experimental Investigation of Suppression Effectiveness on Oil Pool Fire by Water Mist
British Library Conference Proceedings | 2006
|FIRE SUPPRESSION WITH MIST High pressure mist for fire suppression
Online Contents | 2010