Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparison of Wind Pressure Coefficients with Wind Load Provisions
This study has compared the equivalent external pressure coefficients, (GCpf)eq, with 6 wind load provisions and wind tunnel test data. The wind load provisions are the ASCE 7-10, NBCC 2010, AS/NZS 2011, EN 2005, AIJ 2004 and KBC 2009. Experiment data on low-rise building have been obtained at the University of Western Ontario (UWO) to contribute to the NIST aerodynamic database. For the experiment, a model with 1:12 of roof slope and 4.9 and 12.2 m of eave height was used under open terrain conditions. (GCpf)eq was re-normalized based on the external pressure coefficients, GCpf, of ASCE 7-10. When compared to (GCpf)eq of the experiment data with 4.9 m of eave height, consequently, ASCE 7-10 (81%), NBCC 2010 (84%), AS/NZS 2011 (70%), AIJ 2004 (68%) and KBC 2009 (53%) were all underestimated. Among them, KBC 2009 reveals the lowest value. On the contrary, EN2005 was overestimated with 122%. When the eave height was 12.2 m, in addition, the same pattern was observed in most codes. EN2005 was slightly overestimated with 115%.
Comparison of Wind Pressure Coefficients with Wind Load Provisions
This study has compared the equivalent external pressure coefficients, (GCpf)eq, with 6 wind load provisions and wind tunnel test data. The wind load provisions are the ASCE 7-10, NBCC 2010, AS/NZS 2011, EN 2005, AIJ 2004 and KBC 2009. Experiment data on low-rise building have been obtained at the University of Western Ontario (UWO) to contribute to the NIST aerodynamic database. For the experiment, a model with 1:12 of roof slope and 4.9 and 12.2 m of eave height was used under open terrain conditions. (GCpf)eq was re-normalized based on the external pressure coefficients, GCpf, of ASCE 7-10. When compared to (GCpf)eq of the experiment data with 4.9 m of eave height, consequently, ASCE 7-10 (81%), NBCC 2010 (84%), AS/NZS 2011 (70%), AIJ 2004 (68%) and KBC 2009 (53%) were all underestimated. Among them, KBC 2009 reveals the lowest value. On the contrary, EN2005 was overestimated with 122%. When the eave height was 12.2 m, in addition, the same pattern was observed in most codes. EN2005 was slightly overestimated with 115%.
Comparison of Wind Pressure Coefficients with Wind Load Provisions
Lee, Jong-Won (Autor:in) / Kong, Yun-Bae (Autor:in) / Shin, Sung-Woo (Autor:in)
2013
5 Seiten
Aufsatz (Konferenz)
Englisch
Comparison of Wind Pressure Coefficients with Wind Load Provisions
British Library Conference Proceedings | 2014
|Comparison of Wind Load Provisions for Lattice Towers
British Library Conference Proceedings | 1994
|Comparison of Directional and Envelope Wind Load Provisions of ASCE 7
Online Contents | 2014
|Comparison of Directional and Envelope Wind Load Provisions of ASCE 7
British Library Online Contents | 2014
|