Nonlinear Structural Analysis of Fire-Exposed Reinforced Concrete Column
A nonlinear structural analysis is presented for reinforced concrete (RC) columns exposed to fire. The analysis includes two steps: the first step is the calculation of the temperature distribution in concrete members, and the second the determination of the mechanical response due to elevated temperature and applied loading. In the thermal analysis, the effect of moisture is taken into account. The use of the computer program for evaluating the response of a RC column from the initial preloading stage to collapse, due to fire, is illustrated. The validity of the numerical model used in the program is verified by comparing the predictions from the computer program with measured results from full-scale fire resistance tests. The computer program can be used to predict the fire resistance of RC columns for any values of the significant parameters, such as load level, section dimensions, column length, concrete strength, concrete cover, aggregate type and reinforcement ratio.
Nonlinear Structural Analysis of Fire-Exposed Reinforced Concrete Column
A nonlinear structural analysis is presented for reinforced concrete (RC) columns exposed to fire. The analysis includes two steps: the first step is the calculation of the temperature distribution in concrete members, and the second the determination of the mechanical response due to elevated temperature and applied loading. In the thermal analysis, the effect of moisture is taken into account. The use of the computer program for evaluating the response of a RC column from the initial preloading stage to collapse, due to fire, is illustrated. The validity of the numerical model used in the program is verified by comparing the predictions from the computer program with measured results from full-scale fire resistance tests. The computer program can be used to predict the fire resistance of RC columns for any values of the significant parameters, such as load level, section dimensions, column length, concrete strength, concrete cover, aggregate type and reinforcement ratio.
Nonlinear Structural Analysis of Fire-Exposed Reinforced Concrete Column
Advanced Materials Research ; 1095 ; 267-275
20.03.2015
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Fire Resistance of Reinforced Concrete Column Exposed to Fire with Cooling Phase
British Library Conference Proceedings | 2014
|Fire Resistance of Reinforced Concrete Column Exposed to Fire with Cooling Phase
Trans Tech Publications | 2014
|Nonlinear analysis of reinforced concrete cross-sections exposed to fire
British Library Online Contents | 2007
|Textile-reinforced concrete exposed to fire
British Library Online Contents | 2005
|Compressive Strength of Post Fire Exposed Concrete Column Wrapped with Fiber Reinforced Polymer
BASE | 2017
|