Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Penetration Resistance to Chloride Ions of Silica Fume Concrete
The penetration resistance to chloride ions of concrete is one of the important factors affecting the durability of concrete structures. The penetration resistance to chloride ions of concrete is measured with the increasing substitution amount of silica fume in this paper. For the low water-binder ratio of 0.28, 0.30 and 0.32, compared with the reference concrete, with the increase of age, the penetration resistance to chloride ions of concrete can be enhanced with the increasing substitution amount of silica fume, but the increased range is smaller. The penetration resistance of chloride ions of concrete is not necessarily improved by gradually decreasing the water-binder ratio. Considering the substitution amount of silica fume, water-binder ratio and concrete age, the best mix proportions are that the substitution amount of silica fume is 9% or 12% when the water-binder ratio is 0.28 and the substitution amount of silica fume is 12% when the water-binder ratio is 0.30.
Penetration Resistance to Chloride Ions of Silica Fume Concrete
The penetration resistance to chloride ions of concrete is one of the important factors affecting the durability of concrete structures. The penetration resistance to chloride ions of concrete is measured with the increasing substitution amount of silica fume in this paper. For the low water-binder ratio of 0.28, 0.30 and 0.32, compared with the reference concrete, with the increase of age, the penetration resistance to chloride ions of concrete can be enhanced with the increasing substitution amount of silica fume, but the increased range is smaller. The penetration resistance of chloride ions of concrete is not necessarily improved by gradually decreasing the water-binder ratio. Considering the substitution amount of silica fume, water-binder ratio and concrete age, the best mix proportions are that the substitution amount of silica fume is 9% or 12% when the water-binder ratio is 0.28 and the substitution amount of silica fume is 12% when the water-binder ratio is 0.30.
Penetration Resistance to Chloride Ions of Silica Fume Concrete
Applied Mechanics and Materials ; 584-586 ; 1519-1522
04.07.2014
4 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Penetration Resistance to Chloride Ions of Silica Fume Concrete
British Library Conference Proceedings | 2014
|Measurement of chloride penetration into silica fume concrete
Elsevier | 1990
|Chloride Ion Penetration in Conventional Concrete and Concrete Containing Condensed Silica Fume
British Library Conference Proceedings | 1987
|Influence of Silica Fume on Chloride Resistance of Concrete
British Library Conference Proceedings | 1997
|Rapid chloride penetration on high performance fly ash incorporated silica fume concrete