Piled Raft Structure Finite Element Analysis of Composite Foundation Settlement in Da XI Passenger Dedicated Line
Composite foundation settlement of piled raft structure in Da Xi passenger dedicated line is analyzed by the large finite element software MIDAS/GTS and established calculation model of foundation treatment. The problem of pile-soil contact is highlighted in the trail and analyzes the settlement nephogram and pile-soil stress nephogram. On this basis the foundation settlement factors was analyzed systematically that focus on the elastic modulus of pile, pile spacing, pile diameter and pile length in foundation treatment, especially for the characteristics parameters of contact element. Result shows that increasing the pile modulus, pile diameter, pile length and decreasing the pile spacing is all conducive to reducing settlement. The best advice is got that the pile diameter should be not more than 0.5m, pile length not more than 27m and the pile spacing be around 2m.
Piled Raft Structure Finite Element Analysis of Composite Foundation Settlement in Da XI Passenger Dedicated Line
Composite foundation settlement of piled raft structure in Da Xi passenger dedicated line is analyzed by the large finite element software MIDAS/GTS and established calculation model of foundation treatment. The problem of pile-soil contact is highlighted in the trail and analyzes the settlement nephogram and pile-soil stress nephogram. On this basis the foundation settlement factors was analyzed systematically that focus on the elastic modulus of pile, pile spacing, pile diameter and pile length in foundation treatment, especially for the characteristics parameters of contact element. Result shows that increasing the pile modulus, pile diameter, pile length and decreasing the pile spacing is all conducive to reducing settlement. The best advice is got that the pile diameter should be not more than 0.5m, pile length not more than 27m and the pile spacing be around 2m.
Piled Raft Structure Finite Element Analysis of Composite Foundation Settlement in Da XI Passenger Dedicated Line
Advanced Materials Research ; 937 ; 438-443
07.05.2014
6 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Settlement analysis of a large piled raft foundation
British Library Conference Proceedings | 2010
|Investigations of Settlement of Piled Raft Foundation 1.51
British Library Conference Proceedings | 2004
|Settlement Analysis of Piled-Raft Foundation Using Numerical Method
Tema Archiv | 2012
|Settlement Analysis of Piled-Raft Foundation Using Numerical Method
British Library Conference Proceedings | 2012
|Europäisches Patentamt | 2024
|