Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Load-Carrying Capacity of Timber Structure Bolt Connection Subjected to Double Unequal Shears
The paper deals with load-carrying capacity of bolted connections subjected to unequal double shears with thin plates as outer members and inner timber member. There are derived equations which describe the load-carrying capacity of this connection type in the ultimate limit state.
Load-Carrying Capacity of Timber Structure Bolt Connection Subjected to Double Unequal Shears
The paper deals with load-carrying capacity of bolted connections subjected to unequal double shears with thin plates as outer members and inner timber member. There are derived equations which describe the load-carrying capacity of this connection type in the ultimate limit state.
Load-Carrying Capacity of Timber Structure Bolt Connection Subjected to Double Unequal Shears
Applied Mechanics and Materials ; 752-753 ; 711-714
20.04.2015
4 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Reliability of Timber Structure Bolt Connection Subjected to Double Unequal Shears
Trans Tech Publications | 2015
|British Library Conference Proceedings | 2015
|Trans Tech Publications | 2015
|