The Study of Indoor Thermal Environment Characteristics of Office Building Effected by Stratum Ventilation
A typical office building with stratum ventilation as the research object was studied in this paper. CFX Fluid Computation software was used to numerical simulate the characteristics of indoor thermal environment effected by air speeds under 19°C supply air temperature and 8 ventilation rate. The numerical simulate results showed that, the obvious thermal stratification occurred in the vertical direction. Such thermal stratification met the demands of building energy conservation and the human thermal comfort. In this paper, the velocity coefficient and the temperature coefficient were used to evaluate thermal comfort. From the results of the numerical simulation, it could be seen that when the supply air speeds were controlled between 0.5m/s to 0.9m/s, the thermal comfort, as well as the air supply efficiency in the human activity area was relative satisfactory. With the constant fresh air ventilated to the breathing zone, the air quality could be improved.
The Study of Indoor Thermal Environment Characteristics of Office Building Effected by Stratum Ventilation
A typical office building with stratum ventilation as the research object was studied in this paper. CFX Fluid Computation software was used to numerical simulate the characteristics of indoor thermal environment effected by air speeds under 19°C supply air temperature and 8 ventilation rate. The numerical simulate results showed that, the obvious thermal stratification occurred in the vertical direction. Such thermal stratification met the demands of building energy conservation and the human thermal comfort. In this paper, the velocity coefficient and the temperature coefficient were used to evaluate thermal comfort. From the results of the numerical simulation, it could be seen that when the supply air speeds were controlled between 0.5m/s to 0.9m/s, the thermal comfort, as well as the air supply efficiency in the human activity area was relative satisfactory. With the constant fresh air ventilated to the breathing zone, the air quality could be improved.
The Study of Indoor Thermal Environment Characteristics of Office Building Effected by Stratum Ventilation
Applied Mechanics and Materials ; 556-562 ; 803-806
23.05.2014
4 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Savings effected in heating a Cleveland office building
Engineering Index Backfile | 1921
|DOAJ | 2019
|Airflow Characteristics of Stratum Ventilation
Springer Verlag | 2024
|Stratum Ventilation—Low-Carbon Way to Thermal Comfort and Indoor Air Quality
Springer Verlag | 2024
|Stratum ventilation - A potential solution to elevated indoor temperatures
British Library Conference Proceedings | 2009
|