Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Effect of Second Loading on the Instrumented Continuous Flight Auger Concrete Pile on Porous Soil
This paper presents the results of two load tests carried out in a continuous flight auger pile of 0.4 m in diameter and 12 m in length. The pile was instrumented in depth with strain gages in order to obtain the load capacity along the shaft and the tip. The load tests were carried out at the University of Campinas Experimental Site Test. The subsoil where the pile was installed is constituted by a first stratum of Silty Clay, which is porous and collapsible, of 6.5 m in thickness, followed by a stratum of residual soil of Clayey Silt up to 14 m depth. The first load test was the slow type, and a quick load test in the same pile after five days. From the results obtained with the use of instrumentation, the values for both lateral and tip load were determined in each one of test carried out in the pile studied. With these results and applying the Cambefort’s Law, it was could evaluate the evolution of the shaft friction and tip load in relation to the associated settlements, as well as the occurrence of residual load. The ultimate load obtained in the test was 960 kN and 810 kN for the first and second tests, respectively. The stress for the tip was 853 kPa and 655 kPa for the first and second tests, respectively.
Effect of Second Loading on the Instrumented Continuous Flight Auger Concrete Pile on Porous Soil
This paper presents the results of two load tests carried out in a continuous flight auger pile of 0.4 m in diameter and 12 m in length. The pile was instrumented in depth with strain gages in order to obtain the load capacity along the shaft and the tip. The load tests were carried out at the University of Campinas Experimental Site Test. The subsoil where the pile was installed is constituted by a first stratum of Silty Clay, which is porous and collapsible, of 6.5 m in thickness, followed by a stratum of residual soil of Clayey Silt up to 14 m depth. The first load test was the slow type, and a quick load test in the same pile after five days. From the results obtained with the use of instrumentation, the values for both lateral and tip load were determined in each one of test carried out in the pile studied. With these results and applying the Cambefort’s Law, it was could evaluate the evolution of the shaft friction and tip load in relation to the associated settlements, as well as the occurrence of residual load. The ultimate load obtained in the test was 960 kN and 810 kN for the first and second tests, respectively. The stress for the tip was 853 kPa and 655 kPa for the first and second tests, respectively.
Effect of Second Loading on the Instrumented Continuous Flight Auger Concrete Pile on Porous Soil
Key Engineering Materials ; 753 ; 285-289
28.08.2017
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Report on an instrumented continuous flight auger test pile at ascot
British Library Conference Proceedings | 2006
|Full-Scale Loading Tests on Instrumented Continuous Flight Auger (CFA) Piles
British Library Conference Proceedings | 2002
|Just-in-time continuous flight auger piles using an instrumented auger
Tema Archiv | 2002
|Behaviour of Instrumented Hollow Auger Pile Groups in Sandy Soil
Online Contents | 2021
|Bored, continuous flight auger and omega instrumented piles: Behavior under compression
British Library Conference Proceedings | 2005
|