Study of Fire Behavior of a Profiled Sheet-Ceramsite Concrete Composite Floor
In order to study the fire behavior of the profiled sheet-ceramsite concrete composite floor subjected to fire load, research on fire response and post-fire bearing capacity of a profiled sheet-ceramsite concrete composite floor subjected to dead load, which has no shearing nails, is carried out here through experiment. Based on the experimental results, the fire behavior and post-fire bearing capacity of the floor after exposure to fire are analyzed. It is shown that the failure form of the profiled sheet-ceramsite concrete composite floor after exposure to fire has obvious change compared with the floor not subjected to fire load, but the composite floor subjected to fire still exhibits higher bending capacity, and the ultimate value of the equivalent distributed load is up to 35kN/m2, which may be used as basis of strengthening and repairing of the profiled sheet-ceramsite concrete composite floor after exposure to fire.
Study of Fire Behavior of a Profiled Sheet-Ceramsite Concrete Composite Floor
In order to study the fire behavior of the profiled sheet-ceramsite concrete composite floor subjected to fire load, research on fire response and post-fire bearing capacity of a profiled sheet-ceramsite concrete composite floor subjected to dead load, which has no shearing nails, is carried out here through experiment. Based on the experimental results, the fire behavior and post-fire bearing capacity of the floor after exposure to fire are analyzed. It is shown that the failure form of the profiled sheet-ceramsite concrete composite floor after exposure to fire has obvious change compared with the floor not subjected to fire load, but the composite floor subjected to fire still exhibits higher bending capacity, and the ultimate value of the equivalent distributed load is up to 35kN/m2, which may be used as basis of strengthening and repairing of the profiled sheet-ceramsite concrete composite floor after exposure to fire.
Study of Fire Behavior of a Profiled Sheet-Ceramsite Concrete Composite Floor
Advanced Materials Research ; 243-249 ; 5231-5235
17.05.2011
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Study of Fire Behavior of a Profiled Sheet-Ceramsite Concrete Composite Floor
British Library Conference Proceedings | 2011
|Study of Post-Fire Behavior of a Profiled Sheet-Ceramsite Concrete Composite Floor
Trans Tech Publications | 2011
|Test of Fire Response of a Profiled Sheet-Ceramsite Concrete Composite Floor
British Library Conference Proceedings | 2011
|Test of Fire Response of a Profiled Sheet-Ceramsite Concrete Composite Floor
Trans Tech Publications | 2011
|British Library Conference Proceedings | 2011
|