Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Analysis of the Ventilation Effects on Radon-222 Exhalation in a Dead-End Tunnel
The regularity of radon exhalation rate in the over-broken granite tunnel is susceptible to weather conditions and ventilation styles. Based on the calculation model of radon exhalation in tunnel, some experiments have been carried out to analyze the variations of radon exhalation in cases of natural ventilation, blowing ventilation and exhaust ventilation separately. The results show that there is a linear relation between the radon exhalation and the natural ventilation quantity, and also between the radon exhalation and the ambient temperature; the radon exhalation in the case of exhaust ventilation is 63% higher than that in the blowing case under the condition of the same ventilation quantity and ambient temperature. Therefore, it is suggested that operation in the tunnel in high temperature be avoided in summer, and the blowing ventilation be adopted as an effective way for ventilation.
Analysis of the Ventilation Effects on Radon-222 Exhalation in a Dead-End Tunnel
The regularity of radon exhalation rate in the over-broken granite tunnel is susceptible to weather conditions and ventilation styles. Based on the calculation model of radon exhalation in tunnel, some experiments have been carried out to analyze the variations of radon exhalation in cases of natural ventilation, blowing ventilation and exhaust ventilation separately. The results show that there is a linear relation between the radon exhalation and the natural ventilation quantity, and also between the radon exhalation and the ambient temperature; the radon exhalation in the case of exhaust ventilation is 63% higher than that in the blowing case under the condition of the same ventilation quantity and ambient temperature. Therefore, it is suggested that operation in the tunnel in high temperature be avoided in summer, and the blowing ventilation be adopted as an effective way for ventilation.
Analysis of the Ventilation Effects on Radon-222 Exhalation in a Dead-End Tunnel
Applied Mechanics and Materials ; 713-715 ; 304-313
13.01.2015
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Displacement Ventilation - Effects of Movement and Exhalation
British Library Conference Proceedings | 1997
|Monitoring cement hydration using radon exhalation method
Tema Archiv | 2006
|Radon exhalation rate from various building materials
Tema Archiv | 1993
|SAGE Publications | 2016
|