Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Fire Safeguards of “Plastbau” Construction
There are exposed the results of resistance testing on effects of fire in interfloor construction and wall panel made according to “plastbau” system technology out of expandable polystyrene, when they are protected by mortar extension as an insulator. The applied testing method is prescribed by standard form EN 13501-2. Based on testing results, there is affirmed that interfloor construction fulfills resistance criteria on effects of fire of 180 min, and wall panel fulfills resistance criteria on effects of fire of 60 min, when it is protected by mortar extension as an insulator..
Fire Safeguards of “Plastbau” Construction
There are exposed the results of resistance testing on effects of fire in interfloor construction and wall panel made according to “plastbau” system technology out of expandable polystyrene, when they are protected by mortar extension as an insulator. The applied testing method is prescribed by standard form EN 13501-2. Based on testing results, there is affirmed that interfloor construction fulfills resistance criteria on effects of fire of 180 min, and wall panel fulfills resistance criteria on effects of fire of 60 min, when it is protected by mortar extension as an insulator..
Fire Safeguards of “Plastbau” Construction
Applied Mechanics and Materials ; 725-726 ; 138-145
29.01.2015
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Providing safeguards against fire hazards during the construction of buildings
Engineering Index Backfile | 1929
Sanitary safeguards in well construction
Engineering Index Backfile | 1927
|