Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Current Status and Problems of Building Interior Decoration Using Low Formaldehyde-Emitting Materials in Taiwan
Regardless of material regulations at the supply source or post-construction quality inspection systems, certain levels of model management systems have been developed. However, in the hospital waiting room, the measured formaldehyde concentration in the air reached 0.99 ppm, which is 12 times higher than that of the standard value. The formaldehyde emission rates measured in the building materials of the private housings or hospital waiting room ranged from 158 to 238 μg/m2∙h, which exceed both the ABSL and BSMI standards. Moreover, the decoration locations, construction staff, and construction behaviors varied despite their claims of using low formaldehyde-emitting materials. This study compiled the current objectives and regulations established by various supervising authorities and implemented a supporting management system in material grading, amount of material usage, ventilation path control, and ventilation effectiveness for facilitating the promotion of healthy indoor air quality, thereby enhancing public health.
Current Status and Problems of Building Interior Decoration Using Low Formaldehyde-Emitting Materials in Taiwan
Regardless of material regulations at the supply source or post-construction quality inspection systems, certain levels of model management systems have been developed. However, in the hospital waiting room, the measured formaldehyde concentration in the air reached 0.99 ppm, which is 12 times higher than that of the standard value. The formaldehyde emission rates measured in the building materials of the private housings or hospital waiting room ranged from 158 to 238 μg/m2∙h, which exceed both the ABSL and BSMI standards. Moreover, the decoration locations, construction staff, and construction behaviors varied despite their claims of using low formaldehyde-emitting materials. This study compiled the current objectives and regulations established by various supervising authorities and implemented a supporting management system in material grading, amount of material usage, ventilation path control, and ventilation effectiveness for facilitating the promotion of healthy indoor air quality, thereby enhancing public health.
Current Status and Problems of Building Interior Decoration Using Low Formaldehyde-Emitting Materials in Taiwan
Applied Mechanics and Materials ; 775 ; 279-282
20.07.2015
4 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Formaldehyde-free interior decoration integrated wallboard
Europäisches Patentamt | 2020
|Manufacture method of building interior decoration materials
Europäisches Patentamt | 2018
|Interior wall coating mechanism for building interior decoration
Europäisches Patentamt | 2020
|