Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Analytical Investigation on Concrete Filled Double-Skinned Steel Tubular Column Composite Frame with Bolted End-Plate Connections
Simulation studies of seismic behaviour of bolt-endplate connected composite structural systems consisting of CFDST columns and steel beams frame with reinforced concrete slabs are presented in this paper. Based on fiber-section model, analytical models were developed to predict the elastic-to-plastic behaviour of the prototype frame. Analysis results indicated that the structural behaviour under the simulated seismic loadings was consistent with the expected performance objects for different earthquake hazard levels corresponding to current seismic design codes, implying that effective seismic performance of composite CFDST frame with bolted connections can be achieved. The primary analytical simulation shows the suggested bolted endplate CFDST system has the potential to offer appropriate strength and adequate stiffness for buildings located in areas of high earthquake intensity, and provides basic information for further experimental researches to validate the seismic performances of the bolted end-plate CFDST structures.
Analytical Investigation on Concrete Filled Double-Skinned Steel Tubular Column Composite Frame with Bolted End-Plate Connections
Simulation studies of seismic behaviour of bolt-endplate connected composite structural systems consisting of CFDST columns and steel beams frame with reinforced concrete slabs are presented in this paper. Based on fiber-section model, analytical models were developed to predict the elastic-to-plastic behaviour of the prototype frame. Analysis results indicated that the structural behaviour under the simulated seismic loadings was consistent with the expected performance objects for different earthquake hazard levels corresponding to current seismic design codes, implying that effective seismic performance of composite CFDST frame with bolted connections can be achieved. The primary analytical simulation shows the suggested bolted endplate CFDST system has the potential to offer appropriate strength and adequate stiffness for buildings located in areas of high earthquake intensity, and provides basic information for further experimental researches to validate the seismic performances of the bolted end-plate CFDST structures.
Analytical Investigation on Concrete Filled Double-Skinned Steel Tubular Column Composite Frame with Bolted End-Plate Connections
Advanced Materials Research ; 639-640 ; 220-224
11.01.2013
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Conference Proceedings | 2013
|Research Advancements on Blind Bolted Connections to Concrete-Filled Steel Tubular Chords
Springer Verlag | 2025
|Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns
British Library Online Contents | 2006
|Investigations on global buckling behaviour of concrete-filled double-skinned steel tubular columns
TIBKAT | 2018
|