Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Laboratory Tests on Masonry Vaults with Backfill Strengthened at the Extrados
This paper deals with the experimental behavior of two masonry vaults strengthened externally with a composite material. Thickness, internal span and rise of the vaults were 120 mm, 2000 mm and 730 mm, respectively. Masonry was made of solid clay bricks and lime mortar. An alkali-resistant coated glass fiber grid embedded in a cement-based matrix was used as strengthening material. The tensile strength of the glass grid as specified by its manufacturers was about 45kN/m. Both of the tested vaults were strengthened at their extrados. Expanded clay aggregate or lightweight concrete were used as a backfill. The vaults were tested under monotonic vertical loads applied at a quarter span. The main aim of the research presented here was to develop a strengthening method acceptable for vaults with frescoes, to determine the load-carrying capacity and to examine failure modes of the tested specimens. The results of the tests show that observed failure modes depend on the backfill configuration.
Laboratory Tests on Masonry Vaults with Backfill Strengthened at the Extrados
This paper deals with the experimental behavior of two masonry vaults strengthened externally with a composite material. Thickness, internal span and rise of the vaults were 120 mm, 2000 mm and 730 mm, respectively. Masonry was made of solid clay bricks and lime mortar. An alkali-resistant coated glass fiber grid embedded in a cement-based matrix was used as strengthening material. The tensile strength of the glass grid as specified by its manufacturers was about 45kN/m. Both of the tested vaults were strengthened at their extrados. Expanded clay aggregate or lightweight concrete were used as a backfill. The vaults were tested under monotonic vertical loads applied at a quarter span. The main aim of the research presented here was to develop a strengthening method acceptable for vaults with frescoes, to determine the load-carrying capacity and to examine failure modes of the tested specimens. The results of the tests show that observed failure modes depend on the backfill configuration.
Laboratory Tests on Masonry Vaults with Backfill Strengthened at the Extrados
Key Engineering Materials ; 624 ; 510-517
12.09.2014
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Laboratory Tests on Masonry Vaults with Backfill Strengthened at the Extrados
British Library Conference Proceedings | 2015
|Classification of backfill at the extrados of masonry vaults
Online Contents | 2013
|Experimental Tests on Strengthened Masonry Vaults
British Library Conference Proceedings | 2014
|Experimental Tests on Strengthened Masonry Vaults
Trans Tech Publications | 2014
|Structural restoration of vaults with extrados ties
British Library Conference Proceedings | 2005
|