Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental and numerical analysis of fire scenarios involving two mechanically ventilated compartments connected together with a horizontal vent
SummaryThis work deals with an experimental and numerical investigation of a fire scenario involving two rooms mechanically ventilated and connected together with a horizontal vent. The objective is to improve the understanding of the physical phenomena and to assess the capability of computational fluid dynamics (CFD) numerical simulations to predict flow field for such a fire scenario. The study is based on a set of large‐scale fire experiments performed in the framework of the OECD PRISME‐2 project in the DIVA multi‐room facility of the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) and of numerical simulations performed with the ISIS CFD code. The fire scenario consists of two rooms, one above the other, mechanically ventilated and connected to each other with a horizontal vent of 1 m2. The fire is a heptane pool fire located in the lower room. The analysis focuses on the coupling between the burning rate, the flow at the vent, and the configuration of the mechanical ventilation. Several regimes of combustion are encountered from well‐ventilated steady fire to under‐ventilated unsteady and oscillatory fire. The results show that the burning rate is controlled by both the mechanical ventilation and the downward flow from the vent. The numerical simulations highlight the specific pattern of the oxygen concentration field induced by the downward flow at the vent.
Experimental and numerical analysis of fire scenarios involving two mechanically ventilated compartments connected together with a horizontal vent
SummaryThis work deals with an experimental and numerical investigation of a fire scenario involving two rooms mechanically ventilated and connected together with a horizontal vent. The objective is to improve the understanding of the physical phenomena and to assess the capability of computational fluid dynamics (CFD) numerical simulations to predict flow field for such a fire scenario. The study is based on a set of large‐scale fire experiments performed in the framework of the OECD PRISME‐2 project in the DIVA multi‐room facility of the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) and of numerical simulations performed with the ISIS CFD code. The fire scenario consists of two rooms, one above the other, mechanically ventilated and connected to each other with a horizontal vent of 1 m2. The fire is a heptane pool fire located in the lower room. The analysis focuses on the coupling between the burning rate, the flow at the vent, and the configuration of the mechanical ventilation. Several regimes of combustion are encountered from well‐ventilated steady fire to under‐ventilated unsteady and oscillatory fire. The results show that the burning rate is controlled by both the mechanical ventilation and the downward flow from the vent. The numerical simulations highlight the specific pattern of the oxygen concentration field induced by the downward flow at the vent.
Experimental and numerical analysis of fire scenarios involving two mechanically ventilated compartments connected together with a horizontal vent
Fire and Materials
Pretrel, Hugues (Autor:in) / Vaux, Samuel (Autor:in)
Fire and Materials ; 43 ; 514-529
01.08.2019
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2017
|British Library Online Contents | 2017
|British Library Online Contents | 2017
|Toward predictive simulations of pool fires in mechanically ventilated compartments
British Library Online Contents | 2013
|Vent Flows in Fire Compartments with Large Openings
Online Contents | 2007
|